8. A single squeeze tool cannot be guaranteed to provide 100%
closure, where this is required users are advised to consider
using 2 squeeze tools.
Instructions for use.
Fitting
1) Unscrew the 2 check screws until the threads are clear of the
threaded blocks.
2) Locate the pressure control valve on the hydraulic jack. The
tip of the jack handle will connect onto this. Unscrew the
control valve until any internal pressure in the jack is
released. The jack and squeeze bar assembly will be
retracted under the pressure of the return springs.
3) Remove the Bottom bar from the loops in the mainframe
4) Set the limit stop (buffer) plates to the correct pipe diameter
and rating (SDR) of the pipe to be squeezed. If the plates do
not have the correct sizes, check the other set exchange if
necessary. The plates are set correctly when the correct end
face is pointing downwards and positioned to contact the
bottom bar when this is re-fitted.
5) Position the mainframe over the pipe to be squeezed and
slide the bottom bar into the loops of the mainframe beneath
the pipe, position the pipe centrally between the squeeze bar
and bottom bar.
6) Close the pressure control valve by screwing clockwise with
the jack handle.
7) Fit the jack handle into the collar of the pump on the jack.
Commence pumping the jack to apply the squeeze pressure.
9