Wastewater entering the Fusion
during the treatment process. If inorganic in nature, it will be stored within the Fusion
sludge (solids on the bottom) and must be removed periodically to ensure the performance of the Fusion
Maintenance sections part B and C to determine when the maximum depths of scum and sludge have been reached and pumping is required.
Follow the procedures in Figure 20 to remove scum and sludge from the chambers shown below.
Figure 20 - Pumping Procedure
VACCUUM
1
4
Notice: If the sludge in the sedimentation chamber is pumped out first, the water level in the anaerobic chamber goes down simultaneously and the
scum on the filtration will enter the filtration, which may cause clogging. Always pump out the scum and sludge in the anaerobic chamber first.
*Shut off blower before pumping.
1.
Pump out the scum in the anaerobic chamber.
2.
Pump out the sludge built up on the filtration media.
3.
Pump out all the sludge at the bottom of the anaerobic chamber – put the suction hose from the cleaning baffle to the bottom, pump out all
sludge while pressure water cleaning filtration media and chamber walls.
Sedimentation chamber
4.
Pump out the scum by the suction hose while breaking the scum using a stick or equivalent.
5.
Put the suction hose to the bottom and pump out all sludge.
6.
Aerobic contact filtration chamber
Although the chamber may not need to be cleaned, it is possible to pump out the water in the chamber from the storage chamber if
cleaning is needed. Put the suction hose from the storage chamber to the bottom, pump out sludge while pressure water cleaning
contact media, filtration media and chamber walls. When the water in the storage chamber is pumped out, the water level in the
aerobic contact filtration chamber goes down simultaneously since both chambers are connected at the bottom.
7.
After cleaning
Refill water up to the standard level (prescribed line) in the unit. After refilling, restart the blower.
FUSION
contains organic and inorganic materials. If organic in nature, it is treated and decomposed by microorganisms
®
2
5
© Copyright 2014. All rights reserved.
PUMPING
®
. The stored materials accumulate as scum (floating) or
®
3
6
15
. Please review the Operation and
®
TAP WATER
SK3002