Figure 8 - Positioning
4-POINT
LIFTING
LEVEL ACROSS TOP OF UNIT
All large Fusion units are shipped without
risers attached due to size restraints,
therefore all units will need to have the
chosen riser kit attached in the field. Please
see the riser installation instructions below.
Risers come in size ranging from 6" (152 mm)
to 1' (305 mm), under no circumstances can
the risers be extended more than 1' (305 mm)
without consulting the factory.
Riser Installation Instructions -
All Large Units
Install Fusion Unit in the ground and fill with
water checking for any leaks. Back fill with
dirt up to a reasonable working level for
safety and easy of working on hub inserts
and risers. Be careful not to get any back fill
material into Fusion unit.
Hub Inserts for 4" (102 mm) Schedule
40 PVC (American Pipe Size)
Depending on where your Fusion Unit was
shipped from, you may have the Japanese
pipe size hub inserts. You may need to
change them out to the American 4" PVC
schedule 40 pipe size.
18" (457 mm) and 24" (610 mm) Riser Installation Process
Verify tank opening and riser match up by placing the riser over the
chosen access hole. Once it is verified that the riser fits, proceed. (if it
does not fit cut tank opening to match).
Clean tank lip of any dust and dirt and apply provided mastic to tank lip.
Install riser by setting and pressing into the mastic adhesive. Additional
fasteners maybe used to attach riser if needed. Install riser cover with
tamper proof screws.
LESS THAN 60°
60°
LIFTING
HOOK
LIFTING
LEVELING
RISER/CONVERSION KIT INSTALLATION
4" (101 mm) TANK ADAPTER
4" (101 mm) TANK
ADAPTER GASKET
PLACE A BEAD OF
SILICON ON BACK OF
ADAPTER BEFORE
INSTALLING NUT
© Copyright 2014. All rights reserved.
Figure 9
CONCRETE ANCHOR
COLLAR
H
Z
INLET HUB DETAIL, "A"
18" (457 mm) or
24" (609 mm)
DIA RISER COVER
18" (457 mm)
or 24" (609 mm)
DIA RISER
TAR ROPE
SEAL
8
W
PLACE A BEAD OF
SILICON ON BACK OF
ADAPTER BEFORE
INSTALLING NUT
OUTLET HUB DETAIL, "B"
SK2995
SK2931