CLAS OP 0679 Quick Start Manual - Page 6

Browse online or download pdf Quick Start Manual for Service Equipment CLAS OP 0679. CLAS OP 0679 8 pages. 12l aluminium air blaster/bazooka

CLAS OP 0679 Quick Start Manual
OP 0679
12l ALUMINIUM AIR BLASTER/BAZOOKA
INSTRUCTION
Shut the locking and the filling valve and connect the booster to the compressed air
supply.
Open the locking valve until the desired air pressure level is reached. The pressure release
valve opens at 6-8 bar.
Apply the filling cone with its flange to the rim.
APPROACH ANGLE
Choose your angle, so that the deflated air can freely float between tire and rim. A too
narrow/steep angle (onto the rim/bead) will considerably reduce the efficiency of the
operation.

STORAGE AND MAINTENANCE

Hang up the booster to the wall (using a hook). Leave the filling valve open, so that
possible moisture can leave the air tank. Follow your national/regional safety and testing
regulations.
Check the tank and all other mounted components for cracks and damage, regularly.
Never loosen or tighten any components while under pressure.