Acorn Safety S0310-FPB Installation, Operation And Maintenance Instructions - Page 2

Browse online or download pdf Installation, Operation And Maintenance Instructions for Washer Acorn Safety S0310-FPB. Acorn Safety S0310-FPB 7 pages. Pedestal eye/facewash

Installation & Operation Manual

PRELIMINARY STEPS

1. Read the installation instructions prior to beginning the installation.
2. Separate parts from packaging and verify all necessary parts are accounted for and undamaged. Obtain missing or
damaged parts from Acorn Safety prior to beginning installation.
3. Flush water supply lines prior to installation. This will remove unwanted debris from the lines and prevent unwanted
blockages in the safety equipment.
4. In order to comply with ANSI Z358.1, the safety equipment must be inspected periodically. An inspection tag is
provided for documentation purposes.
5. all employees at risk of contamination should be informed and trained in the use of this and any other safety
equipment. The signage provided should be posted appropriately in close proximity to this equipment.
ROUGH-IN
FLANGE MOUNTING
DETAIL
Acorn Safety
a division of Acorn Engineering Company™
Manual #7109-214-001
11 1 2 "
[292]
1
Ø7
"
2
[191]
3
Ø
"
8
[10]
1
Ø9
"
8
[232]
1-1/4" NPT
WASTE
8"
[203]
3/4" NPT
FEMALE SUPPLY
BLEED HOLE
OUTLET
S0310-FPB24 SHOWN FOR
REFERENCE
FREEZE RESISTANT
VALVE
GENERAL NOTES:
1.
ALL DIMENSIONS ARE IN INCHES [MM].
2.
STANDARD DEPTHS ARE 24, 36 AND
48 INCHES. OTHERS AVAILABLE
31 1 2 "
UPON REQUEST.
[800]
BURY DEPTH
SEE NOTE 2
NOT LESS THAN 3 CUBIC FT.
OR POROUS FILL AROUND AND
BELOW BLEED OUTLET FOR
DRAINAGE. DO NOT USE SAND.
Page 2 of 7
Date: 10/28/2013