BLADEZ ION 150 Troubleshooting Procedures - Page 5

Browse online or download pdf Troubleshooting Procedures for Scooter BLADEZ ION 150. BLADEZ ION 150 12 pages. Electric power board
Also for BLADEZ ION 150: Product Handbook (13 pages)

BLADEZ ION 150 Troubleshooting Procedures
Check Charger Base
Place red probe on the charger pot and the black probe to the charger connector (black wire) as shown, the reading should be ~ 0.2 Ω.
Do the same checking to the same connector (red wire), the reading should be over 1 kΩ. If open circuit (OL) is detected, the charger
base is bad.