ABBERFIELD INDUSTRIES - C22 coin validators TECHNICAL DETAILS
As well as validating coins the device can control other machines via a number of inputs and outputs.
Special software programmes can be provided to meet specific industry or customer needs. Then the
instruction label each side of the coin validator changes to satisfy the specific application. Two typical
applications are for photocopier control and car park boom gate control and many others are possible.
PHOTOCOPY CONTROL
ABBERFIELD
INDUSTRIES
ABBERFIELD
INDUSTRIES
32 Cross Street, Brookvale
Sydney 2100 Australia
T: (61) (02) 9939 2844
F: (61) (02) 9938 3462
Label on Control Board Side
BOOM GATE CONTROL
SECURITY
SCREW
SERIAL #
........................
PROGRAM
....................
{
VERSION
........................
BATCH #
.........................
{
12
{
11
Reset car
{
10
count
9
Car park full
bypass
Count
8
price 2
decrement
select
7
Count
loop
increment
6
+ Common
5
Boom gate
4
3
2
Car park full
1
Common
ABBERFIELD
INDUSTRIES
ABBERFIELD
INDUSTRIES
32 Cross Street, Brookvale
Sydney 2100 Australia
T: (61) (02) 9939 2844
F: (61) (02) 9938 3462
Label on Control Board Side
32 Cross St, Brookvale, Sydney NSW 2100, Australia
OPERATING PROGRAMMES
COIN VALIDATORS
22P
BOOM GATE CONTROL
SERIES:
SETTING PRICES
show car
count
Power off - Set dip switches up.
+
bypass
Power on - Display shows PAr.
price 2
select
- Set dip switches down.
- Push SET button.
+
loop
PO on display (price one).
+12V
- Push SET button.
+
}
RS485
Current price one on display
(last digit flashing 00.0
+
TXD
- To change push NEXT until
RXD
new figure shown (0 to 9).
OV
- Push SET
(next digit flashes 00.
- Repeat above for all digits.
Display returns to P0.
- Push NEXT for next price.
- Repeat above for price 2
(P0 to P1) P2, P3 and P5 are
operating parameters, P4 sets
car park capacity.
- When prices are set Power off
- Reset dip switches to operating
position. Power on.
DIP SWITCHES
PUSH BUTTONS
ELIMINATE
ON
SET
VALIDATE
OFF
Tel: (02) 99392844 Fax: (02) 99383462 Email: [email protected]
page 8
32 Cross Street, Brookvale
SYDNEY, NSW, 2100
AUSTRALIA
TEL: (61) (02) 9939 2844
Fax: (61) (02) 9938 3462
www.abberfield.com.au
0
).
0
0).
32 Cross Street, Brookvale
SYDNEY, NSW, 2100
AUSTRALIA
TEL: (61) (02) 9939 2844
Fax: (61) (02) 9938 3462
www.abberfield.com.au
NEXT
Brochure # 083-3
Label on Power Supply
Label on Power Supply