Setting Time of Day

Installer Settings

Programming Screens

Push NEXT until time of day screen is displayed.
Press and hold ▼ until SET TIME is displayed and the hour flashes.
Press ▲ or ▼ until the correct hour is displayed.
Then press NEXT. The minutes will flash. Press ▲ or ▼ until the
correct minute is displayed.
Press NEXT to return to the User Displays.
In the event of a power outage that is less than 8 hours, the control
valve will remember all settings and time of day.
After 8 hours, the only item that needs to be reset is the time of day
(indicated by the time of day flashing). All other settings are
permanently stored in the control valve's nonvolatile memory.
If a power loss occurs that is less than 8 hours and the time of day
flashes, this indicates that the battery is depleted. The time of day
should be reset and the non-rechargeable battery should be replaced.
The battery is a 3 Volt Lithium Coin Cell type 2032. Time of day
should be reset when Daylight Savings Time starts / ends.
To enter Installer Display press NEXT and ▲ simultaneously for
about 5 seconds and release.
Day Override: sets the number of days between regenerations. Set
Day Override using ▲ or ▼ (1 to 28). Default is 3 Days
Press NEXT to go to step 3I. Press REGEN to return to previous
step.
Regeneration Time (hour): Set the hour of day for regeneration
using ▲ or ▼. The default time is 12:30 am.
Press NEXT to go to step 4I. Press REGEN to return to previous
step.
Regeneration Time (minutes): Set the minutes of day for
regeneration using ▲ or ▼. The default time is 12:30 am.
Press NEXT to exit Installer Display Settings. Press REGEN to
return to previous step.