7. TECHNICAL DATA
Standard code
Data points
CO
specifications
2
Measurement principle
Sensor Type
Working range
Accuracy at 25 °C and 1013 mbar
Response Time
Temperature dependency
Measuring time interval
Calibration interval
Built-in temperature sensor
Temperature working range
Accuracy
Conversion Gain
Electrical specifications
Power supply
Power consumption (standby mode)
Power consumption (measuring mode)
Connection type
Communication
Protocol type
Baud rate
Data length
Housing
Material
Color
Protection
Weight
Installation type
TF6581_A_NOT_INST_C02_SENSOR_MODBUS
105s with measured data averaging 60s without measured data averaging
1h (default), use Synch operation (Modbus register table) for immediate measurement
8. WARRANTY
This guarantee is valid for two years from the original date of purchase of your appliance, for faults
of the appliance, which have been caused by faulty construction. On these conditions, Aereco
guarantee the replacement or the supply of the equipment found to be defective after inspection by
its after sales service. In any case, the warranty may not cover additional costs, of labour, transport
or compensation of any kind. The warranty does not cover damage due to improper installation
in this manual, improper use or attempted repair by unauthorized personnel. In case of problems,
please contact your installer or your reseller.
9. CONFORMITY AND STANDARD
The S-C02/T sensor is CE certified.
The S-C02/T sensor complies with the following regulatory references:
Directives
EMC
S-C02/T Modbus sensor
CAP1668
CO
and temperature
2
NDIR (non-dispersive infrared technology)
Dual wavelength
0...2000 ppm C0
2
< ± (50 ppm +2 % of measuring value)
typ. 2ppm CO2/°C (0...50°C / 32...122°F)
>5 years
2°C to 50°C
0.5°C ensured at 25°C
10mV/°C
12 VDC
10mA
135mA Max
2xRJ45 shielded
Modbus RTU, RS485 physical layer
9600bps
16bits
ABS
white
IP 20
80.5g
Ceiling and Wall-mounted,indoor
Standards
EN 61000-6-3 : 2007 / A1 : 2011
EN 61000-6-1 : 2007
7 / 8
Aereco S.A.