ARO PE05P-X-X-B0S Series Operator's Manual - Page 2

Browse online or download pdf Operator's Manual for Water Pump ARO PE05P-X-X-B0S Series. ARO PE05P-X-X-B0S Series 12 pages. 1/2” diaphragm pump

ARO PE05P-X-X-B0S Series Operator's Manual
READ, UNDERSTAND AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.
EXCESSIVE AIR PRESSURE
STATIC SPARK
WARNING EXCESSIVE AIR PRESSURE. Can cause person-
al injury, pump damage or property damage.
S
Do not exceed the maximum inlet air pressure as stated on the
pump model plate.
S
Be sure material hoses and other components are able to with-
stand fluid pressures developed by this pump. Check all hoses
for damage or wear. Be certain dispensing device is clean and
in proper working condition.
WARNING STATIC SPARK. Can cause explosion resulting in
severe injury or death. Ground pump and pumping system.
S
PE05P-XDS-XXX-B0S and PE05P-XES-XXX-B0S Groundable
Acetal pumps: Use the pump ground lug provided. Connect to
a 12 ga. (minimum) wire (kit is included) to a good earth ground
source.
S
Sparks can ignite flammable material and vapors.
S
The pumping system and object being sprayed must be
grounded when it is pumping, flushing, recirculating or spray-
ing flammable materials such as paints, solvents, lacquers,
etc. or used in a location where surrounding atmosphere is
conducive to spontaneous combustion. Ground the dispens-
ing valve or device, containers, hoses and any object to which
material is being pumped.
S
Secure pump, connections and all contact points to avoid
vibration and generation of contact or static spark.
S
Consult local building codes and electrical codes for specific
grounding requirements.
S
After grounding, periodically verify continuity of electrical path
to ground. Test with an ohmmeter from each component (e.g.,
hoses, pump, clamps, container, spray gun, etc.) to ground to
insure continuity. Ohmmeter should show 0.1 ohms or less.
S
Submerse the outlet hose end, dispensing valve or device in
the material being dispensed if possible. (Avoid free streaming
of material being dispensed.)
S
Use hoses incorporating a static wire.
S
Use proper ventilation.
S
Keep inflammables away from heat, open flames and sparks.
S
Keep containers closed when not in use.
WARNING Pump exhaust may contain contaminants. Can
cause severe injury. Pipe exhaust away from work area and per-
sonnel.
S
In the event of a diaphragm rupture material can be forced out
of the air exhaust muffler.
S
Pipe the exhaust to a safe remote location when pumping haz-
ardous or inflammable materials.
S
Use a grounded 3/8" minimum i.d. hose between the pump and
the muffler.
WARNING HAZARDOUS PRESSURE. Can result in serious
injury or property damage. Do not service or clean pump,
hoses or dispensing valve while the system is pressurized.
S
Disconnect air supply line and relieve pressure from the sys-
tem by opening dispensing valve or device and / or carefully
and slowly loosening and removing outlet hose or piping from
pump.
WARNING HAZARDOUS MATERIALS. Can cause serious in-
jury or property damage. Do not attempt to return a pump to the
Page 2 of 12

OPERATING AND SAFETY PRECAUTIONS

HAZARDOUS MATERIALS
HAZARDOUS PRESSURE
factory or service center that contains hazardous material.
Safe handling practices must comply with local and national
laws and safety code requirements.
S
Obtain Material Safety Data Sheets on all materials from the
supplier for proper handling instructions.
WARNING EXPLOSION HAZARD. Models containing alumi-
num wetted parts cannot be used with 1,1,1-trichloroethane,
methylene chloride or other halogenated hydrocarbon sol-
vents which may react and explode.
S
Check pump motor section, fluid caps, manifolds and all
wetted parts to assure compatibility before using with solvents
of this type.
CAUTION Verify the chemical compatibility of the pump
wetted parts and the substance being pumped, flushed or re-
circulated. Chemical compatibility may change with tempera-
ture and concentration of the chemical(s) within the
substances being pumped, flushed or circulated. For specific
fluid compatibility, consult the chemical manufacturer.
CAUTION Maximum temperatures are based on mechani-
cal stress only. Certain chemicals will significantly reduce
maximum safe operating temperature. Consult the chemical
manufacturer for chemical compatibility and temperature lim-
its. Refer to Pump Data on page 1 of this manual.
CAUTION Be certain all operators of this equipment have
been trained for safe working practices, understand it's limita-
tions, and wear safety goggles / equipment when required.
CAUTION Do not use the pump for the structural support of
the piping system. Be certain the system components are
properly supported to prevent stress on the pump parts.
S
Suction and discharge connections should be flexible connec-
tions (such as hose), not rigid piped, and should be compatible
with the substance being pumped.
CAUTION Prevent unnecessary damage to the pump. Do
not allow pump to operate when out of material for long periods
of time.
S
Disconnect air line from pump when system sits idle for long
periods of time.
CAUTION Use only genuine ARO replacement parts to as-
sure compatible pressure rating and longest service life.
NOTICE
Install the pump in the vertical position. The
pump may not prime properly if the balls do not check by grav-
ity upon start-up.
NOTICE
Re-torque all fasteners before operation. Creep
of housing and gasket materials may cause fasteners to loos-
en. Re-torque all fasteners to insure against fluid or air leakage.
NOTICE
Replacement warning labels are available upon
request: "Static Spark" PN \ 93616-1, "Diaphragm Rupture" PN
\ 93122.
= Hazards or unsafe practices which could
WARNING
result in severe personal injury, death or
substantial property damage.
= Hazards or unsafe practices which could
CAUTION
result in minor personal injury, product or
property damage.
= Important installation, operation or
NOTICE
maintenance information.
PE05P-X-X-B0S (en)