Blanca Atmospheric Water Maker User Manual - Page 10
Browse online or download pdf User Manual for Water Filtration Systems Blanca Atmospheric Water Maker. Blanca Atmospheric Water Maker 16 pages. Atmospheric water generators desktop unit
UV light
1. Power Off and unplug unit. Separate rear cover. (loosen & remove 2
screws with Phillips screwdriver)
2. Remove filters. (See water filter replacement)
3. Disconnect the housing of the U.V from ballast.
4. Remove U.V from U.V clip carefully.
(There may be water in hose, fitting and U.V)
5. Pull to remove U.V while pushing the adaptor of the fitting in
opposite direction.
6. Install a new U.V.
7. After U.V exchange, reset the U.V replacement function by using
Menu/Set button. (see page 13)
Note: DO NOT look at UV ray with naked eyes
Air filter
1. Separate air filter bracket by
loosening 2 easy screws with
hand or Phillips screwdriver.
(Image 5-1)
2. Remove air filter and replace
with new air filter. (Image 5-2)
3. After air filter exchange, reset
the air filter replacement
function by using Menu/Set
button. (see page 13)
Water Generating Capacity
Humid.
50%
Temp.
15
3.2
20
5.2
25
6.6
30
8.4
Image5-1
Daily Water Production in Lab (liters/day)
60%
70%
4.1
5.9
5.8
7.2
8.3
11.7
11.5
16.1
9 9
Image5-2
80%
90%
6.4
8.3
8.2
11.3
13.9
17.0
18.2
23.0