Aerial AD 650 Manual - Page 14
Browse online or download pdf Manual for Dehumidifier Aerial AD 650. Aerial AD 650 16 pages.
3) The complete dryer is out of operation. Fan and compressor does not run.
- Is the dryer switched on? The On-/Off-switch must be in position `I´ and must light
up.
- Is the unit supplied with voltage? The On/Off-switch must light up in Pos. `I´.
Check the main cable, an additional cable, the socket and the main fuse.
- The humidity value adjusted at the hygrostat is achieved. The dryer will start again
after exceeding the adjusted humidity.
- Water collecting bucket is full: The red neon lights up (see 6.3 „operation panel").
Empty the water bucket and put it back into the unit. (see 6.5 „condensate outlet")
- The AMP-blind-plug is not fixed in the AMP-socket or a pump-out-kit is not
installed correctly. (see 6.6 „condensate pump")
4) Strong icing up at the evaporator.
- Put the dryer into a room with min. +10° C room temperature and wait until
complete ice is defrosted. Switch on the unit again (in that room with min. +10° C)
and let work for approx 3 hours. If there is icing up again, please contact your
dealer. Otherwise make sure that the unit is only been used in rooms with more
than +3° C. Also the storage of the dehumidifier at inadmissible temperature
conditions can lead to damages / problems while immediate switch-on.
5) The humidity adjusted at the hygrostat does not become achieved and/or the
device does not switch off automatic.:
- Is the hygrostat adjusted on a value lower than 40 – 45% r.h.? Humidity values
with a minimum of 40 % - 45 % r.h. can be achieved with a condensation dryer.
Adjust the hygrostat to a reachable value.
- Is the unit with enough capacity for your application? The air changing, number of
the persons in the room and open water surfaces decide on the humidity burden
in the room. Let calculate the necessary capacity from your dealer
- Is there a lot of water in the walls or the floor? In that case the dryer needs some
time to remove that water and to achieve an acceptable humidity in that room.
ATTENTION
The appliance must be repaired by trained and expert personnel only. In the case
of interventions by unauthorized people, any and all warranty claims shall become
null and void!
If you have any questions regarding defects and malfunctions of AERIAL-air dryers
we recommend get in touch with your supplier.
The producer AERIAL GmbH you reach under 0049-40-526879-0 or www.aerial.de
11. Disposal
Please do not dispose this unit with the domestic waste and
please do not dispose this unit in the environment.
We dispose this unit for you – free of charge and
environment-friendly. Please contact us!
Alternative your local waste management enterprise takes
this unit for environment-friendly disposal.
page 14 of 15