Aerial AP 50 Instruction Manual - Page 13
Browse online or download pdf Instruction Manual for Dehumidifier Aerial AP 50. Aerial AP 50 17 pages. Swimming pool dehumidifier
Also for Aerial AP 50: Instruction Manual And Warranty (14 pages)
![Aerial AP 50 Instruction Manual](/uploads/products/server2/77601/77601.jpg)
7.Technical data
Among other things, many different components which are installed in the
condensation dryer decide on the capacity of the device. Since these components
can never be completely identical, in accordance to DIN EN 810 the capacity may
deviate up to 5% of specified capacity.
General:
Operational range:
Protection class:
Voltage :
Fusing in swimming halls: residual-current-operated circuitbreaker (r.c.c.b) has
AP 50
Air volume
Noise level
dimensions (width/height/depth)
weight
refrigerant (CFC-free)
Temperature / relative humidity capacity
30°C / 80%r.h.
30°C / 60%r.h.
27°C / 60%r.h.
20°C / 60%r.h.
AP 70
Air volume
Noise level
dimensions (width/height/depth)
weight
refrigerant (CFC-free)
Temperature / relative humidity capacity
30°C / 80%r.h.
30°C / 60%r.h.
27°C / 60%r.h.
20°C / 60%r.h.
+10°C up to + 32°C / 40% r.h. up to 95% r.h.
IP X4
230 V / 50 Hz
to be installed
875 m³/h
50 dB(A)
824 mm / 740 mm / 261 mm
54 kg
R134a / filling charge see type plate
Capacity in acc. to DIN EN 810 E
l/day
47,0
29,0
27,0
24,0
1000 m³/h
52 dB(A)
1024 mm / 740 mm / 261 mm
64 kg
R134a / filling charge see type plate
Capacity in acc. to DIN EN 810 E
l/day
66,2
46,0
34,6
32,0
page 13 of 17
Power
consump.
l/kW
Watt
770
2,6
715
1,7
670
1,68
630
1,6
Power
consump.
l/kW
Watt
1.050
2,6
990
1,9
920
1,57
870
1,53
kW/l
0,393
0,596
0,596
0,630
kW/l
0,38
0,516
0,638
0,652