CAMDEN CM-634 Series Installation Instructions - Page 2
Browse online or download pdf Installation Instructions for Keypad CAMDEN CM-634 Series. CAMDEN CM-634 Series 4 pages. Vandal resistant piezo keypads
1 To set new master code
Enter **1 2 3 4**
The keypad enters programming mode, the red LED
flashes
Enter 2
The red LED illuminates for 2 seconds and then flashes
Enter 0-0-0#
The red LED illuminates for 2 seconds and then flashes
Enter new 4-8 digit code
This is the new master code. Record the number and
keep in a secure location
Enter #
The red LED illuminates for 2 seconds and then flashes
Re-enter the new master code
The red LED illuminates for 2 seconds and then flashes
Enter # Enter #
To exit programming mode
2. To set a new user code
Enter **master code**
The keypad enters programming mode, the red LED
flashes
Enter 2
The red LED illuminates for 2 seconds and then flashes
Enter address of new user code i.e. 001 (001-200
accepted)
Enter #
The red LED illuminates for 2 seconds and then flashes
Enter new 4-8 digit user code
This is the new user code. Record the number and
position. Keep in a secure location
Enter #
The red LED illuminates for 2 seconds and then flashes
Re-enter the new 4-8 digit user code
The red LED illuminates for 2 seconds and then flashes
Enter #
The new code is added. To add new codes continue
from second step, changing the address each time.
When finished enter an additional # to exit programming
mode
Re-enter 2 to set the next code, or press # to EXIT
3. To remove an individual user code
Only the user codes address are removable, the master
code may be changed but not removed
Enter **master code**
The keypad enters programming mode, the red LED
flashes
Enter 3
The red LED illuminates for 2 seconds and then flashes
Enter address to be removed
le-001 (001 – 200 accepted)
Enter #
The red LED illuminates for 2 seconds and then flashes
Enter address to be removed again
le-001 (001 – 200 accepted)
Enter #
The red LED illuminates, flashes & the code is removed
Enter #
To exit programming
4. To remove all user codes
Enter **master code**
The keypad enters programming mode, the red LED
flashes
Enter 4
The red LED illuminates for 2 seconds and then flashes
Enter master code
Enter #
The red LED illuminates for 2 seconds and then flashes
for 40 seconds. All code addresses are removed
Enter #
To exit programming
5. To set door open time
Enter **master code**
The keypad enters programming mode, the red LED
flashes
Enter 1
The red LED illuminates for 2 seconds and then flashes
Enter door open time
(01-99) Ex. 05 = 5 seconds
Enter #
The red LED illuminates for 2 seconds and then flashes
Enter #
To exit programming
6. To set output relay to latching mode (On-Off)
Enter **master code**
The keypad enters programming mode, the red LED
flashes
Enter 1
The red LED illuminates for 2 seconds and then flashes
Enter 00
Enter #
The red LED illuminates for 2 seconds and then flashes
Enter #
The relay is set to latching mode
To program the relay for a timed output, please refer to
programming option #5
7. To set remote door opening time
Enter **master code**
The keypad enters programming mode, the red LED
flashes
Enter 5
The red LED illuminates for 2 seconds and then flashes
Enter door open time
(01-99) Ex. 05 = 5 seconds
Enter #
The red LED illuminates for 2 seconds and then flashes
Enter #
To exit programming