FACTORY WIRING
230V (AC) Gearmotor

POWER SUPPLY

120 / 230 V AC 50/60 Hz
SIGNALING DEVICES
Flashing light connection output (contact
rated at: 230 V AC - 25 W max).
Additional light connection output (contact
rated at: 230 V - 60 W max).
See function F18.
E1 EX W
L
N
U V W
Condenser
Opening limit-switch
micro-switch
L
N
L1T L2T CT VS VF
C A
M E
E1 EX W
L
N
FC FA F
Closing limit-switch
micro-switch
COM
Red
SP
Gray
4
Black
3
24
2
17
1
White
0
FR
Brown
0
24V
0 10 11 TS 1 2 3 3P 4 5 7 CX CY CZ
24V
U V W
+ E -
COM
NC
NC
 To vary the motor torque, move
the shown faston to one of the four
positions; from 1 (min.) to 4 (max.).
Blue
Orange
0
10 11
0 10 11 TS 1 2 3 3P 4 5 7 CX
24V
FC FA F
Accessories power
supply output 24 V
AC, max 20 W.
Gate open signal
output (contact rated
at: 24 V AC - 3 W
max).
See function F10.
+ STB -
A B GND