CAME C-BXE Installation Manual - Page 6
Browse online or download pdf Installation Manual for Door Opening System CAME C-BXE. CAME C-BXE 20 pages. Automation for industrial closures
Also for CAME C-BXE: Manual (16 pages)

5.4 Installing the automation on sectional doors
The following applications are only examples, as the space for installing the ratiomotor and accessories varies accord-
ing to obstructions. It is thus up to the system installer to select the most suitable solution.
DIRECT TRANSMISSION - The
Fig.1
CBX ratiomotor is supplied
ready for installation with a
direct action on the door springs
shaft, with a shaft diameter of 1
inch (fi g. 1); for special volume
requirements, it is also possible
to install it horizontally (fi g. 2)
but for both cases use accessory
(Art. C006).
Fig.2
C006
VERTICAL APPLICATION
HORIZONTAL APPLICATION
1) Before securing the ratiomotor, open the protection cover to facilitate
post-assembly operations.
C A
M E
1
2
2) Insert the ratiomotor on the spring pole using the handle on the
ratiomotor.