5.5 Mounting
- Secure the base plate to the pillar using ø8 screws and ø14 moulded inserts making sure the minimum distance of 150mm from the
ground is met.
- Secure the A bracket (using ø8 screws or by welding) to the gate leaf making sure the 450mm and 19mm distances measurements and
are met.
Pillar
Bracket "A"
ø 14 mm
ø 8 mm
ø 8 mm
450 mm
Front view
- Insert the gearmotor into the base plate and secure it using the two supplied M8x110 screws and M8 nuts.
M8x110
M8