CAME BPT MTMA/IP Programming Manual - Page 14

Browse online or download pdf Programming Manual for Control Unit CAME BPT MTMA/IP. CAME BPT MTMA/IP 17 pages.

CAME BPT MTMA/IP Programming Manual

Operations on PCS/XIP

The device is part of a system based on the Xip system. The system structure must be built using PCS/XIP software.
Device view
XIP Multi server
Server
Main MTMV IP
Built-in buttons
Aux
MTM8C
Main MTMA IP
Built-in buttons
Aux
MTM8C
IP block 1
IP sub block
Unit IP 1
Unit IP 2
IP Unit 3
IP Unit 4
Block MTMV IP
Built-in buttons
Aux
MTM8C
Unit view
2
6
Devices
Server
ETI/miniSER/Domo XIP
DVC IP
DC IP
1
MTMV IP
MTMA IP
Area
Concierge
C
MTMV IP properties
Name
Address
D
ID
Addressing mode
5
IP address
Talk time (s)
Ring time (s)
SIP username
Door opening time (s)
Twilight indicated by
Door open alarm time (s)
Door open contact
Lift management aux
Door opener entry notifi cation
Customise the use of tones
Door status
Plate active
Main MTMV IP
224.4.0
111111
Static
192.168.1.3
60
30
008000
01024
2
<None>
Inactive
Normally open (NO)
No event
Disabled (default)
Door status (default)
Plate active (default)