Installing The Genius-II Power Supply
Personnel
Installation is to be carried out only by suitably qualified personnel.
Ventilation, Orientation, and Thermal Considerations
The preferred orientation is with the cooling fins vertical and located such that
there is a minimum of 80 mm free air space above and below them. This allows
for the lowest operating temperature of the internal electronics and hence the
highest reliability of the product.
The final enclosure must also provide adequate ventilation to the outside world (or
larger internal cavity) to prevent excessive heating of the air within the enclosure.
The unit is rated to provide full power in both vertical and horizontal orientations
with enclosure air temperatures up to 50 C.
Note: The enclosure air temperature can easily exceed 50 C if adequate
ventilation is not provided.
The unit has over-temperature protection, meaning it will shut down if its internal
temperature rises above a safe level. The unit will automatically restart once it has
cooled to an acceptable level.
WARNING: Do not install unit in same compartment where flammable
material such as petrol is stored.
Mounting
The Genius-II should be securely mounted to a suitably strong surface, using the
two pre-drilled mounting brackets. Dimensional details are provided in Figure 1
below.
Mains Cable
WARNING: If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in order to avoid a
hazard.
This is pre-cabled and fitted with AS/NZ mains plug ready for connection to an
internal 240 V GPO. Ensure that the connection to the mains supply is in
accordance with the national wiring rules, and that the earth connection is
installed.