Alto Carpetmaster 579 Operator's Manual - Page 11

Browse online or download pdf Operator's Manual for Vacuum Cleaner Alto Carpetmaster 579. Alto Carpetmaster 579 20 pages.

PROBLEM
The machine does not run.
The machine does not
remove debris from the floor.
The brush does not rotate.
CLARKE TECHNOLOGY Operator's Manual 579 Carpetmaster

HOW TO CORRECT PROBLEMS IN THE MACHINE

1. There is no power
1. The filter bag is dirty.
2. There is an obstruction in
the standpipe.
3. There is an obstruction in the
hose.
4. There is an obstruction in the
air tunnel.
5. The tank gasket is worn or broken.
6. The brush does not turn clockwise
when seen from the right-hand
side of the machine.
7. The brush setting is not correct.
8. The brush is worn.
9. The foam filter is dirty.
1. There is an obstruction in the
brush housing.
2. There is an obstruction in the bear-
ings on the end of the brush.
3. The belt is broken or loose.
4. There is low line voltage.
5. The brush drive motor will not run.
CAUSE
ACTION
1. There is an obstruction. See
"Circuit Breaker" in the manual.
2. The electrical outlet, power cord,
electrical switches and motor
brushes are to be checked. Elec-
trical inspections must be made
by a person authorized to do
maintenance. Electrical repairs
must be made by a person
authorized to make electrical repairs.
1. If the bag is ¾ full, discard the
paper bag. clean the bag if it is a
cloth bag. If the machine is used
to pick up heavy debris, discard
or clean the bag before it is ¾ full.
1. Remove the hose from the stand-
pipe tube.
2. Start the vacuum motor.
3. Hold your hand over the stand-
pipe tube. If you feel no suction,
the standpipe has an object in it.
4. Shut off the vacuum motor.
5. Remove the object.
1. Remove the hose from the stand-
pipe tube.
2. Remove the obstruction.
1. Check the air tunnel.
2. Replace the gasket if it is worn or
broken.
1. Check the entire gasket (top,bottom, and
sides) where the front
tank seals against the rear tank.
2. Replace the gasket if it is worn or
broken.
1. Return the machine to a Clarke Technology
Service Branch or a Clarke Technology
Service Center to have the motor
wired correctly.
1. Change the brush setting. If the
brush is set too low on a deep pile
carpet, the housing can stop the
air flow.
1. Replace the brush.
1. Clean the foam filter.
1. Remove the obstruction.
1. Remove the obstruction.
1. Replace or tighten the belt.
1. Remove other appliances on the
line or provide a separate circuit.
1. Push the circuit breaker button.
Page 11