Alto TW 1400 HD Operating Instructions Manual - Page 10

Browse online or download pdf Operating Instructions Manual for Vacuum Cleaner Alto TW 1400 HD. Alto TW 1400 HD 12 pages. Spray extraction cleaner
Also for Alto TW 1400 HD: Operating Instructions Manual (12 pages)

Alto TW 1400 HD Operating Instructions Manual

TROUBLESHOOTING

Fault
Motor does not run
‡ Weak spraying force
‡ Weak suction force
10
Cause
> Power supply
interrupted
> Spray nozzle clogged
> Filter in fresh water
tank clogged
> Fresh water tank
empty
> Pressure pump
defective
> Lid not fitted correctly
on dirty water tank (air
leaks)
> Nozzle clogged
> Suction hose
connections not
correctly fitted (air
leaks)
> Dirty water tank is full.
Float stops suction
flow
> Air filter clogged
> TW 1400 HD only:
Dirty water drain hose
not closed
Remedy
Check mains lead,
plug socket, fuse
Clean and/or descale
nozzle
Clean
Refill. Beforehand,
empty dirty water tank
• Call Alto technician or
authorised specialist
Fit lid tightly; check
gasket
Clean
Check
Empty dirty water tank
Clean
Close