Float Voltage. Controls the target voltage for float stage. Adjustment spans from 13.0 to 13.8 volts.
.
F v
Default is based on battery program selected. To reverse direction of scroll, release magnet and wait for
LED to display Fv code. Re-activate switch and release when desired value is indicated.
.
Float Time. Controls time setting for float mode. Standard value set is 18 minutes. Settings are from 6
F 1
c
minutes to 12 hours. To reverse direction of scroll, release magnet and wait for LED to display F1c code.
Re-activate switch with magnet and release when desired value is indicated.
.
A L
L
Low Voltage Alarm. Allows the user to set the trigger voltage for the low voltage alarm. Default set-
ting for the Low Voltage Alarm is 12.7 volts.
.
Field Threshold - Bulk To Absorption To Float . Controls the criteria used to determine field
F b
A
output required to maintain calculated charging mode. Factory set at 65% field output. Raising "FbA"
shortens calculated bulk charge time. Lowering "FbA" increases calculated bulk charge time. Span of ad-
justment is 16% to 96%. To reverse direction of scroll, release magnet and wait for LED to display "FbA"
code. Re-activate switch and release when desired value is indicated.
.
Field Threshold - Float To Absorption . Controls the criteria used to determine the field current
F F
L
threshold required to cycle between float and absorption charging modes. Factory set at 65%. Raising
"FFL" increases calculated float charge time. Adjusted in 1% increments. Span of adjustment is 16% to
96%. To reverse direction of scroll, release "FFL" code. Reactivate switch with magnet and release when
desired value is indicated.
.
Alternator Temperature Threshold. Controls the setpoint at which point field current is reduced
A L
1
when the the alternator temperature sensor indicates an over-temp condition at the alternator. Requires
temperature sensor installation. Preset at 108˚.
.
Battery Temperature Threshold. Controls the setpoint at which point field current is discontinued
B 1
L
when the the battery temperature sensor indicates an over-temp condition at batteries being sensed.
Requires temperature sensor installation. Preset at 52°C.
.
Slope Voltage Correction. Adjusts the voltage (in milivolts) the regulator uses when monitoring
SL
P
battery temperature sensing. Can be custom adjusted to meet the needs of unique battery technologies.
Consult with battery manufacturer for specific slope voltage recommendations.
START DELAY (SECS.)
SOFT RAMP (SECS.)
BULK VOLTAGE
BULK TIME (MINIMUM)
ABSORPTION VOLTS
ABSORPTION TIME (MINIMUM)
FLOAT VOLTS
FLOAT TIME (MINIMUM)
FLOAT TIME (MAXIMUM)
HIGH VOLTAGE ALARM (VOLTS)
LOW VOLTAGE ALARM (VOLTS)
MAX BAT. TEMP.
MAX ALT. TEMP.
Default Program Settings By Battery Type
UFP
FDC
1
1
60
60
14.1
14.6
18 MIN
18 MIN
13.9
14.4
18 MIN
18 MIN
13.4
13.4
18 MIN
18 MIN
12 HRS.
12 HRS.
15.2
15.6
12.7
12.7
125˚F/52˚C
125˚F/52˚C
226˚F/108˚C
226˚F/108˚C
- 12 -
GEL
AGM
1
1
60
60
14.1
14.38
18 MIN
18 MIN
13.9
14.18
18 MIN
18 MIN
13.7
13.4
18 MIN
18 MIN
12 HRS.
12 HRS.
15.1
15.38
12.7
12.7
125˚F/52˚C
125˚F/52˚C
226˚F/108˚C
226˚F/108˚C
OPS
1
60
14.6
18 MIN
14.4
18 MIN
13.4
18 MIN
12 HRS.
15.6
12.7
125˚F/52˚C
226˚F/108˚C