Balmar Max Charge MC-612 Installation And Operator's Manual - Page 4
Browse online or download pdf Installation And Operator's Manual for Marine Equipment Balmar Max Charge MC-612. Balmar Max Charge MC-612 12 pages. Multi-stage marine regulator
Also for Balmar Max Charge MC-612: Installation And Operation Manual (17 pages)
VI. PRESET BATTERY PROGRAMMING
In addition to its Universal (default) factory program, which can be used safely with
most battery types, the MC-612 features programs for: gel, standard lead acid,
deep-cycle lead acid, AGM (absorbed glass mat), Optima (spiral), as well as voltage-
sensitive (halogen) applications.
'ACTIVATE-RELEASE'
Refers to the activation and immediate deactivation of the
switch by lowering a magnetic tool (such as a pocket screwdriver with a magnetic
tip -- see Figure 9) onto the upper corner of the switch, and immediately deacti-
vating the switch by removing the magnet from the switch. An LED dot, described
in Figure 9 will indicate switch activation.
'ACTIVATE-HOLD ... RELEASE'
requires holding the magnet to the switch until desired values are shown on the
display. Once the desired setting is reached, the magnet is removed to deactivate
the switch.
Note: Program function will alternately cycle up or down each time the PrA Mode is activat-
ed. If you miss your desired program value, release the switch and re-activate, the cycling
direction will automatically change. Any advanced programming values will be retained with-
in the regulator's memory until the preset battery programming is reset.
The MC-612 is equipped with a magnetic reed switch,
embedded in the epoxy potting, which activates the
regulator's programming. The switch works in two
specific actions, described in the shaded box below:
To set the regulator for your desired battery program:
1.
'ACTIVATE-HOLD' the switch. The display will show
the "Pro" mode, indicating that the Program mode
has been activated.
2.
'HOLD' while the display scrolls, until the numeric
equivalent to your battery type is displayed on the
LED screen. See Figure 10 to determine which
selectable preset program is most desirable for your
battery technology. Figure 11 provides detailed infor-
mation regarding preset programs.
3.
'RELEASE' when the desired value is attained.
4.
Once a value has been chosen, the display will return
to the "Pro" mode. At this point, you can adjust, up or
down, by repeating Steps 1 through 3 until the
numeric display reflects your desired preset program.
If no changes are made, the program you have selected will be locked into permanent memory until modified. The "SAV"
code will be displayed, indicating the program has been locked into memory.
Primary Program Settings
Mode
Start Delay (Seconds)
Ramp Up (Seconds)
Bulk Voltage (Max)
Bulk Time (Minimum)
Absorption Voltage
Absorption Time (Minimum)
Float Voltage
Float Time (Maximum)
High Voltage Alarm
Low Voltage Alarm
Max Battery Temperature
Max Alternator Temperature
Equalization (User Prog.)
F F i i g g u u r r e e 1 1 1 1 - Preset program values. Voltages shown may vary by +/- 3% from values shown.
Typically used during programming, this action
F F i i g g u u r r e e 9 9 - Operation of mag-
netic reed switch.
PRG-1
PRG-2
Universal
Deep Cycle
Factory
Flooded
Program
Lead Acid
45
45
60
60
14.10
14.60
36 min.
36 min.
13.90
14.40
36 min.
36 min.
13.42
13.35
6 hr.
6 hr.
15.20
15.60
12.80
12.80
125F/52C
125F/52C
225F/107C
225F/107C
Yes
Yes
Indicates 'ACTIVATE'
PRG-3
PRG-4
Gel
Absorbed
Cell
Glass
Mat (AGM)
45
45
60
60
14.10
14.38
36 min.
36 min.
13.90
14.18
36 min.
36 min.
13.70
13.38
6 hr.
6 hr.
15.10
15.38
12.80
12.80
125F/52C
125F/52C
225F/107C
225F/107C
No
No
- 4 -
SD Mode 1 - Manufacturer name.
Readout displays "BAL".
SD Mode 2 - Regulator model.
Readout displays "612".
SD Mode 3 - Battery type. Readout
displays program currently in memory.
SD Mode 4 - Battery type. Readout
displays abbreviated battery type.
SD Mode 5 - Charging stage. Shows
current stage of charging cycle. See
Figure 12 on Page 5.
SD Mode 6 - Battery voltage.
Displays current battery voltage state.
SD Mode 7 - Calculated voltage.
Readout displays voltage target
based on charging stage.
F F i i g g u u r r e e 8 8 - Short display (SD).
Universal Factory Program
1
(UFP). For multiple battery types.
Flooded Deep Cycle (Fdc). For
2
deep-cell lead acid batteries.
Sealed Gel Cell (GEL). For
3
sealed gel batteries.
Absorbed Glass Mat (AGL). For
4
AGM batteries.
Optima (OPS). For Optima spiral
5
wound batteries.
Flooded Standard (FSB). For
6
standard lead acid batteries.
Halogen (HAL). For voltage
7
sensitive applications.
F F i i g g u u r r e e 1 1 0 0 - Selectable battery presets.
PRG-5
PRG-6
Optima
Standard
Spiral
Flooded
Wound
Lead Acid
45
45
60
60
14.60
14.40
36 min.
36 min.
14.40
14.20
36 min.
36 min.
13.40
13.40
6 hr.
6 hr.
15.60
15.40
12.80
12.80
125F/52C
125F/52C
225F/107C
225F/107C
No
Yes
PRG-7
Halogen
Voltage
Sensitive
45
60
14.00
36 min.
13.80
36 min.
13.50
6 hr.
15.00
12.80
125F/52C
225F/107C
No