Alto-Shaam 1000-MH2-1 Installation, Operation And Maintanance - Page 15

Browse online or download pdf Installation, Operation And Maintanance for Food Warmer Alto-Shaam 1000-MH2-1. Alto-Shaam 1000-MH2-1 16 pages.

Alto-Shaam 1000-MH2-1 Installation, Operation And Maintanance

TrOubLeShOOTINg

Before looking any further, please check the power supply to the unit and controller temperature setting.

ALArmS

The controller is equipped with internal visual and audio alarms:
Press any button on the controller to silence an alarm. Verify that the
closed and the gasket is sealing correctly. If this doesn't solve the problem, please call a qualified technician.
Alarm Displayed
T r O u b L e S h O O T I N g
Description
Door Open Alarm
Condenser High Temperature Alarm
High Temperature Safety Stat
High Temperature Alarm
Low Temperature Alarm
Probe T1 Failure
Probe T2 Failure
Probe T3 Failure
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
dIScoNNEcT UNIT FRoM
powER SoURcE BEFoRE
cLEANINg oR SERVIcINg.
**
**
**
**
**
**
**
**
M R 2 - 1 • M N - 3 6 2 4 6 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 1 3 .
T I T L e
d A N g E R
indicator is lit. If lit, verify that the door is
Action Required
Close door
Check for blockage / clean
Repair / replace relay
Press a button to cancel / check
Press a button to cancel / check
Replace Probe
Replace Probe
Replace Probe