6. Technical data
Measuring input
DC current:
Standard ranges 4...20 mA
Limit values
0...0.1 to 0...40 mA
also live-zero,
start value > 0 to ≤ 50% final va-
lue
– 0.1...0...+ 0.1 to
–20...0...+ 20 mA
max. span: ≤ 40 mA
also bipolar asymmetrical
R
DC voltage:
Limit values
0...0.06 to 0...40,
also live-zero,
start value > 0 to ≤ 50% final va-
lue
– 0.06...0...+ 0.06 to
–20...0...+ 20 V,
max. span: ≤ 40 V
R
Overload:
DC current
continuously 2-fold
DC voltage
continuously 2-fold
12
(7)
(8)
(9)
without
function
ON
= 15 Ω
i
= 100 kΩ
i
Measuring output
DC current:
Standard ranges
4...20 mA, 0 ... 20 mA
invert
20 ... 4 mA, 20 ... 0 mA
Burden voltage/
external resistance:
Standard version,
20 V / R
Ex version,
15 V / R
Current limiter at
Approx. 1.1 ×I
R
max.:
ext
Voltage limiter
= ∞:
at R
Approx. 26 V
ext
Residual ripple in
output current:
< 0.5% p.p.
Response time:
< 50 ms
Power supply H
AC/DC power pack (DC and 45...400 Hz)
Table 1: Nominal voltages and tolerances
Nominal voltage U
Tolerance
N
24... 60 V DC/AC
DC – 15...+ 33%
85...230 V
DC/AC
1
AC ± 15 %
24... 60 V DC/AC
85...230 V AC
± 10%
85...110 V DC
– 15 ... + 10%
For power supply > 125 V, the auxiliary circuit should include an
1
external fuse with a rating ≤ 20 A DC.
≤ 1.2 W resp. ≤ 3 VA
Power input:
Accuracy data (acc. to DIN/IEC 770)
Limit error ≤ ± 0.2%
Basic accuracy:
Including linearity and reproduci-
bility errors
Installation data
Terminals:
DIN/VDE 0609
Screw terminals with wire guards,
for light PVC wiring and
max. 2 ×0.75 mm
Permissible vibrations: 2 g acc. to EN 60 068-2-6
3 ×50 g
Shock:
2 shocks each in 6 directions acc.
to EN 60 068-2-27
Electrical insulation:
All circuits (measuring input/measu-
ring output/power supply) are elec-
trically insulated
max. 1000 Ω
ext
max. 750 Ω
ext
AN
Instruments
version
Standard
(Non-Ex)
In
type of
protection
intrinsically safe
[EEx ia] IIC
or 1 × 2,5 mm
2
2