esera auto connect 11221 User Manual - Page 6

Browse online or download pdf User Manual for Dimmer esera auto connect 11221. esera auto connect 11221 7 pages. 1-wire dual dimmer 1 with pushbutton inputs (extension input)

Pushbutton interface input:
Button interface channel 1 = 1, button interface channel 2 = 2, module button channel 1 = 4, module button
channel 2 = 8, value 16 - 128 no function (always 0)
Dimmer output:
Output 1 = 1, output 2 = 2, output 3 = 4, output 4 = 8, output 5 = 16, output 6 = 32,
Output 7 = 64, output 8 = 128.
Data output:
1_OWD1_1|1
1_OWD1_2|10000001
1_OWD1_3|16
1_OWD1_4|28
Further information on the possibilities and commands can be found in the current documentation
1-Wire Controller /1-Wire Gateway.
12
Operating conditions
The module may only be operated at the voltages, ambient conditions and temperatures specified
and consumers. The operating position of the device is preferably vertical.
The device is intended for use in dry and dust-free rooms.
If condensation water forms, wait for at least 2 hours to acclimatize.
Assemblies and components must not be handled by children!
The modules may only be put into operation under the supervision of a qualified electrician.
In commercial facilities the accident prevention regulations of the association of the commercial trade
associations for electrical systems and equipment must be observed.
Do not operate the module in an environment in which flammable gases, vapors or dusts are present or could be
present.
13
Assembly
The installation site must be protected from moisture. The device may only be used in dry indoor areas in
protected outdoor areas.
The device is intended for installation inside a control cabinet as a stationary device.
14
Disposal instructions
Do not dispose of the device in domestic waste! Electronic devices are to be disposed of
according to the Directive on waste electrical and electronic equipment (WEEE) on local
authorities and collection points for waste electronic equipment!
15
Safety instructions
When using products that come into contact with electrical voltage, the valid VDE regulations must be
observed, especially VDE 0100, VDE 0550/0551, VDE 0700, VDE 0711 and VDE 0860
All final or wiring work must be carried out with the power turned off.
Before opening the device, always unplug or make sure that the unit is disconnected from the mains.
Components, modules or devices may only be put into service if they are mounted in a contact proof housing.
During installation they must not have power applied.
Tools may only be used on devices, components or assemblies when it is certain that the devices are disconnected
from the power supply and electrical charges stored in the components inside the device have been discharged.
Live cables or wires to which the device or an assembly is connected, must always be tested for insulation faults or
breaks.
If an error is detected in the supply line, the device must be immediately taken out of operation until the faulty cable
has been replaced.
When using components or modules it is absolutely necessary to comply with the requirements set out in the
accompanying description specifications for electrical quantities.
If the available description is not clear to the non-commercial end-user what the applicable electrical characteristics
for a part or assembly are, how to connect an external circuit, which external components or additional devices can
be connected or which values these external components may have, a qualified electrician must be consulted.
It must be examined generally before the commissioning of a device, whether this device or module is basically
suitable for the application in which it is to be used.
In case of doubt, consultation with experts or the manufacturer of the components used is absolutely necessary.
For operational and connection errors outside of our control, we assume no liability of any kind for any resulting
damage.
All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of
ESERA GmbH. Errors and technical modification subject to change. ESERA GmbH, ESERA-Automation 2020
www.esera.de
=> Controller No._Module No._Data set | Decimal value Input
=> Controller No._Module No._Data set | Binary representation Input
=> Controller No._Module No._Data set | Dimmer value channel 1 stage 16
=> Controller No._Module No._Data set | Dimmer value channel 2 stage 28
11221 V2.0 R1.0 Manual