Browse online or download pdf User Manual for Control Unit esera automation Shutter Pro V4. esera automation Shutter Pro V4 7 pages. For external roller shutters, awnings, blinds or venetian blinds and 1-wire bus system w/auto-e-connect

esera automation Shutter Pro V4 User Manual
3
Auto-E-Connect® Support
The ESERA Auto-E-Connect® 1-Wire Plug and Play system will be used for the
1-Wire Bus supported. This enables fully automatic configurations of 1-Wire sensors
and actuators on the 1-Wire bus. It is optimized for industrial applications and
enables significant added value beyond the sensor and chip data.
The Auto-E-Connect function automatically recognizes ESERA chips, sensors and actuators, starts suitable
libraries and outputs fully formatted data.
The Auto-E-Connect functionality will be available from mid 2020 via 1-Wire Controllers, 1-Wire Gateways and
1-Wire ECO from ESERA available.
Further information on ESERA Auto-E-Connect can be found on the ESERA website, ESERA Config-Tool 3, or in
the download area for this article in the ESERA Webshop.
4
Technical data
Type:
Number of channels:
Switching voltage:
Switching current:
Switching capacity:
Safety switch-off:
Control input function:
Control inputs:
Isolation:
Function 1-Wire:
Interface:
Operating voltage:
Current consumption:
Display:
Insulation voltage:
Connection:
Note:
To operate the module, a 12 V supply voltage is necessary. For the power supply of the module we
recommend the use of a 1-Wire Hub Art. No. 11322 or 11323
The cables of the control inputs must be electrically insulated from the motor control cable.
5
Ambient conditions
Temperature (operation): 0°C to +50°C
Air humidity:
Dimensions:
Protection system:
Protection class:
6
Conformity
EN 50090-2-2
EN 61000-4-2, ESD
EN 61000-4-3, HF
EN 61000-4-4, Burst
EN 61000-4-5, Surge
EN 61000-6-1, fault-free operation
EN 61000-6-3, stray radiations
RoHS
All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of
ESERA-Automation or E-Service GmbH. Errors and technical modification subject to change. ESERA-Automation, E-Service GmbH 2020
www.esera.de
Tubular motor with limit switches and separate connections for up/down
1, groups can be controlled via isolating relays up to the max. module current.
5 to 230V DC or AC voltage
max. 5A (internal fuse 5A slow blow)
max. 1150VA
switch-off after 120 seconds
1. roller shutter or awning operation: control inputs for upwards, stop, downwards
2. external blinds or venetian blinds: button, short for tilting movement, button, long for
upwards movement, Stop, Down
During motor operation, the control inputs and module buttons can be used to stop the
movement.
Digital / binary input, 10-30VDC, max. 10mA, pulse duration min. 40ms, e.g. for push
button switch (NO contact)
Inputs isolated from 1-Wire interface and power supply
Relay outputs isolated from 1-Wire bus and power supply
Up, stop, downwards, tilting movement through time control up / downwards and stop
1-Wire Bus with Ground/GND, Data and +12V, DS2408 Command set
Feedback for output status and digital / binary input (pushbutton interface)
12V= (+/-10%),
12V max. 30 mA (output active)
LED for „up" and „down", flashes when slats moving up or down
min. 500VAC among 1-Wire bus and relay contact (motor voltage)
Screw terminals (up to 2.5 mm² wire cross section)
10 - 92% (non condensing)
35 x 90 x 70mm (BxHxD)
IP20
III
11231 V2.0 R1.0 Manual