esera automation Auto-E-Connect 11118 User Manual - Page 2
Browse online or download pdf User Manual for Adapter esera automation Auto-E-Connect 11118. esera automation Auto-E-Connect 11118 4 pages. 1-wire adapter 1 for 1-wire cable temperature sensors
4
Technical data
Connection:
Supply voltage:
Other:
Temperature,Operation: 0°C to +50°C
Air humidity:
Dimensions:
Protection class:
Protection system:
5
Conformity
EN 50090-2-2
EN 61000-4-2, ESD
EN 61000-4-3, HF
EN 61000-4-4, Burst
EN 61000-4-5, Surge
EN 61000-6-1, Fault-free operation
EN 61000-6-3, Stray radiation
RoHS
6
Assignment RJ12 socket (temperature sensor)
The RJ12 modular socket (6-pin, RJ12) is designed for direct connection of the 1-Wire
cable temperature sensors 11106 and 11107. The modular socket is assigned as
follows (view into the socket, i.e. on the contact surfaces of the socket)
Assignment RJ12 socket:
PIN
Function
1 + 2
Ground
3 + 4
1-Wire Data
5 + 6
+5 V
7
Assignment Screw terminal (1-Wire network)
Screw terminals +5V, 1-Wire Data and GND are provided for connection to the 1-Wire network.
The assignment is printed on the printed circuit board.
8
Operating conditions
The module may only be operated at the voltages and ambient conditions specified for it. The device can be
operated in any position. The device is intended for use in dry and dust-free rooms.
If condensation forms, wait up to 2 hours for the device to acclimatise.
Assemblies and components must not be handled by children!
The modules may only be put into operation under the supervision of a qualified electrician.
In commercial facilities, the accident prevention regulations of the Association of Industrial Employers' Liability
Insurance Associations for electrical systems and equipment must be observed.
Do not operate the module in an environment in which flammable gases, vapours or dust are or may be present.
9
Assembly
The installation site must be protected against moisture. The device may only be used in dry indoor rooms and in
protected outdoor areas. The device is intended for mounting inside a switch cabinet as a stationary device. The
printed circuit board is open and not electrically insulated, therefore an insulated mounting to metal surfaces and
other electrical cables must be provided.
All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of
ESERA GmbH. Errors and technical modification subject to change. ESERA GmbH, ESERA-Automation 2020
www.esera.de
- RJ11/12 socket for cable temperature sensors
- Screw terminals for 1-Wire network
5VDC
Back-up capacitor 0.1µF between +5V and GND
10 - 92% (non condensing)
40 x 22 x 25 mm
III
IP00
11118 V1.0 R1.0 Manual
Page 2 of 4