dixell CX620 Installing And Operating Insructions - Page 5

Browse online or download pdf Installing And Operating Insructions for Temperature Controller dixell CX620. dixell CX620 5 pages. Microprocessor based controller suitable for applications on medium or low temperature refrigerating units
Also for dixell CX620: Installation And Operating Instructions Manual (6 pages)

dixell CX620 Installing And Operating Insructions
17 Default setting values
Label
Name
Set Set point
Hy
Differential
LS
Minimum set point
US
Maximum set point
Ot
Thermostat probe calibration
Third probe presence (1st cond.
P3P
probe)
O3
Third probe calibration
Fourth probe presence (2nd cond.
P4P
probe)
O4
Fourth probe calibration
odS Outputs activation delay at start up
AC
Anti-short cycle delay
Ac1 Second compressor delay
Compressor ON time during fast
CCt
freezing
CCS Set point for continuous cycle
Con Compressor ON time with faulty probe
Compressor OFF time with faulty
CoF
probe
CH
Kind of regulation
CF
Temperature measurement unit
rES Resolution (integer/decimal point)
rEd Remote display
dLy Display temperature delay
dFP Probe selection for defrost termination
dtE Defrost termination temperature
idF Interval between defrost cycles
MdF (Maximum) length for 1° defrost
dFd Displaying during defrost
dAd MAX display delay after defrost
AUXILIARY THERMOSTAT
ACH Kind of action for auxiliary relay
SAA Set Point for auxiliary relay
SHy Differential for auxiliary relay
ArP Probe selection for auxiliary relay
Sdd Aux.output working during defrost
ALP Probe setting for temperature alarm
ALC Temperature alarms configuration
ALU MAXIMUM temperature alarm
ALL minimum temperature alarm
AFH Temperature alarm and fan differential
ALd Temperature alarm delay
dAo Delay of temperature alarm at start up
Probe for temperat. alarm of
AP2
condenser
AL2 Condenser for low temperat. alarm
AU2 Condenser for high temperat. alarm
Differential for condenser temperature
AH2
alarm recovery
Ad2 Condenser temperature alarm delay
Delay of cond. temper. alarm at start
dA2
up
Compressor off because of condenser
bLL
low temperature alarm
Compr. off for condenser high
AC2
temperature alarm
AUXILIARY OUTPUT
tbA Alarm relay disabling
oA3 Fourth relay configuration
AoP Alarm relay polarity (oA3=ALr)
i1P Digital input polarity
i1F
Digital input configuration
did Digital input alarm delay
1592026000 XW20K GB R2.0 08.06.2011.doc
Range
REGULATION
LS; US
[0.1 to 25.5°C]
[1 to 45°F]
[-55.0°C to SET]
[-67°F to SET]
[SET to 150°C]
[SET to 302°F]
[-12 to 12°C]
[-21 to 21°F]
n=not present; Y=pres.
[-12 to 12°C]
[-21 to 21°F]
n=not present; Y=pres.
[-12 to 12°C]
[-21 to 21°F]
0 to 255 min
0 to 30 min
0 to 255 sec
0.0 to 23h50min, res. 10 min
[-55.0 to 150.0°C]
[-67 to 302°F]
0 to 255 min
0 to 255 min
CL; Ht
DISPLAY
°C; °F
in; dE
P1; 1r2
0.0 to 20min00sec, res. 10 sec
DEFROST
nP; P1; P2; P3; P4
[-50.0 to 150°C]
[-58 to 302°F]
1 to 120 h
0 to 255 min
rt; it; SEt; dEF; dEG
0 to 255 min
CL; Ht
[-55.0 to 150°C]
[-67 to 302°F]
[0.1 to 25.5°C]
[1 to 45°F]
nP; P1; P2; P3
n; Y
ALARMS
P1; P2; P3; P4
rE; Ab
[-55.0 to 150.0°C]
[-67 to 302°F]
[-55.0 to 150.0°C]
[-67 to 302°F]
[0.1 to 25.5°C]
[1 to 45°F]
0 to 255 min
0.0 to 23h50min, res. 10 min
nP; P1; P2; P3; P4
[-55.0 to 150.0°C]
[-67 to 302°F]
[-55.0 to 150.0°C]
[-67 to 302°F]
[0.1 to 25.5°C]
[1 to 45°F]
0 to 254 min , 255=nU
0.0 to 23h50min, res. 10 min
n(0); Y(1)
n(0); Y(1)
n=no; Y=yes
ALr = alarm; dEF = do not select it;
Lig =Light; AUS =AUX; onF=always
on; Fan= do not select it; db = do
not select it; dF2 = do not select it
oP; CL
DIGITAL INPUT
oP=opening;CL=closing
EAL; bAL; PAL; dor; dEF; Htr; AUS
0 to 255 min
Label
Number of activation of pressure
nPS
switch
Default Level
Compress and fan status when open
odC
door
-5.0
- - -
Regulation restart with door open
rrd
2.0
Pr1
alarm
HES Differential for Energy Saving
-50.0
Pr2
110
Pr2
Adr Serrial address
PbC Kind of probe
0.0
Pr1
onF on/off key enabling
dP3 Third probe display
n
Pr2
dP4 Fourth probe display
rSE Current set point
0
Pr2
rEL Software release
Ptb Map code
n
Pr2
0
Pr2
0
Pr2
1
Pr1
5
Pr2
0.0
Pr2
-5
Pr2
15
Pr2
30
Pr2
CL
Pr1
°C
Pr2
dE
Pr1
P1
Pr2
0
Pr2
P2
Pr2
8.0
Pr1
6
Pr1
30
Pr1
it
Pr2
30
Pr2
CL
Pr2
0.0
Pr2
2.0
Pr2
nP
Pr2
n
Pr2
P1
Pr2
rE
Pr2
10.0
Pr1
10.0
Pr1
2.0
Pr2
15
Pr2
1.3
Pr2
P4
Pr2
-40
Pr2
110
Pr2
5
Pr2
15
Pr2
1.3
Pr2
n
Pr2
n
Pr2
Y
Pr2
Lig
Pr2
CL
Pr2
CL
Pr1
dor
Pr1
15
Pr1
XW60K
Name
Range
0 to 15
no; FAn; CPr; F_C
n; Y
[-30 to 30°C]
[-54 to 54°F]
OTHER
1 to 247
PtC; ntC
nu, oFF; ES
--
--
-
- - -
- - -
Default Level
15
Pr2
F-C
Pr2
Y
Pr2
0
Pr2
1
Pr1
ntC
Pr2
oFF
Pr2
-
Pr1
-
Pr1
Pr1
-
Pr2
-
Pr2
5/5