ClearOne VERSA PRO CT Quick Start Manual - Page 14
Browse online or download pdf Quick Start Manual for Conference System ClearOne VERSA PRO CT. ClearOne VERSA PRO CT 17 pages. Professional av solution for huddle rooms

VERSA PRO CT
BMA CTH
1
Item No.
1
Speakers Out: Two Phoenix Euroblock connectors used to connect 2 external speakers.
2
PoE In: Connects PoE Injector to provide power to the BMA CTH.
WARNING: Power over Ethernet (PoE) equipment used with CONVERGE® Huddle must meet
the IEEE 802.3af or 802.3at standards. A 56V 640mA ClearOne PoE Power Injector (Part No.
910-3200-202) should be used. Power sourcing equipment complying with these standards
follow a procedure for negotiating whether power should be supplied. Non-compliant power
sourcing equipment may apply power immediately and could damage the CONVERGE®
Huddle.
Also, ensure that the PoE is connected as the last step, after plugging in all other cables
during initial installation of the BMA CTH.
3
Power Select: Determines power source—either PoE In or P-Link In
4
P-Link In: provides power, audio, and control for peripheral devices.
5
P-Link Out: connects to another P-Link device that requires power. Users can chain one BMA
CTH to a BT EX.
CONNECTING THE BMA CTH TO THE CONVERGE® HUDDLE
In order to use the BMA CTH, you must connect it to the CONVERGE® Huddle. To do so, perform the
following steps.
1.
If you haven't done so already, remove your BMA CTH from its packaging.
2.
Install the BMA CTH in the required location.
3.
Connect the BMA CTH to the CONVERGE® Huddle.
4.
Using Pro Console, configure the BMA CTH as required.
2
3
Description
4
5
14