Fig. 6 Diagram of the connection of fireplace to central heating closed system
13
12'
1. Kamin Vulkan (zadnja strana)
2. Dimna cev
3. Ventil
4. Zatvoren ekspanzioni sud
5. Manometar
6. Radijatorski ventil
7. Radijator
8. Ozračni ventil
6. OPERATION – FIRING
Solid fuel must be physically separated from the fireplace with some space and physical
barrier. Ashtray vessel must be made of non-combustible materials and located out of
the place with stored fuel.

6.1. FIRST FIRING

At the first firing, following conditions must be observed:
Ÿ
chimney must be cleaned and properly connected to the fireplace,
Ÿ
fireplace and heating installation must have installed all safety devices,
Ÿ
system must be filled with water and vented,
Ÿ
within the operating mode of the fireplace, burner door must be closed, and ashtray
Ÿ
positioned into the position behind the limiter – completely closed
automatic draught regulator button must be set to desired value,
Ÿ
maximal fireplace operating temperature is 90° C.
Ÿ
IMPORTANT NOTE: At the first firing, some condensation may occur – water
dripping and occurrence of humidity within the ashtray. In such case, gradually
increase temperature in fireplace and this will stop.
5
11
2
12
10
15
14
4
6
7
3
9
9. Cirkularna pumpa
10. Sigurnosni ventil
11. Potisni vod
12. Priključni vod za vodovodnu mrežu
12'. Odvod tople vode
13. Sonda termoventila
14. Priključak za punjenje i pražnjenje 1/2''
15. Povratni vod
6
8