Dixon Automatic Tool SKC-PTA-BE50F Operation And Maintenance Manual - Page 12

Browse online or download pdf Operation And Maintenance Manual for Power Screwdriver Dixon Automatic Tool SKC-PTA-BE50F. Dixon Automatic Tool SKC-PTA-BE50F 17 pages. Automatic industrial cordless brushless power torque screwdrivers

3. Set up functions
Settings
SL
Screw list from U1~U9
Screw count number from 1-99
SC
Count method: count down
When a batch completed, OKALL alarm signal will last for 0.1 ~ 9.9 sec.
At
Meanwhile buzzer and OK ALL alarm signal will active simultaneously.
RC
Slow Start Time Run down Control (0.1 ~ 9.9 Sec)
Slow start speed (L0/L1/L2/L3/L4/L5/L6/L7/L8/L9)
SP
L0:100%
HC
Maximum Fasten Thread (00.1~99.9)
LC
Minimum Fasten Thread (00.0 ~ 99.8)
Ht
Max. fastening time 0.10 ~ 9.99 sec.
Min fastening time 0.00 ~ 9.98 sec.
When LT set as 0.00. LCD will show OK with green LED on when
Lt
tightening time is correspond to HT setting.
When LT set as 0.01 sec. LCD will show NOK with buzzer alarm, when
tightening time exceed HT setting.
When fastening no. of thread is smaller than LS setting, it will judge this
LS
fastening as double and will not count this fastening.
When fastening error occurred, the LCD panel will display NOK, Buzzer
alarming and the LED is red.
NS
It needs to unlock by the Confirm function (S key) to go on the next
action.
When the OK ALL status occurs, the LCD panel will display AS,
AS
BUZZER alarming and the LED is green. It needs to unlock by the
Confirm (S key) function to go on the next action.
GR
Set gear ratio
->SL->SC->At-> RC->SP->HC->LC->Ht->Lt->LS->NS->AS->GR->END
Step1: Install battery and press [S] for 3 sec. to enter program.
->SL->SC->At-> RC->SP->HC->LC->Ht->Lt->LS->NS->AS->GR->END
Step2: Press [S] to set next function.
Step3: Use up or down key to increase or decrease value. When setting NS and AS, there are only 2
selections, which are [Y] and [N]. [Y]= yes [N]= no
Step4: When setting completes and display END, parameters will be saved and the display will flicks twice
and return to main screen.
Functions
Description
L1~L9:30%~90%
11
Default
setting
U1
05
2.0 sec.
0.0 sec.
L0
99.9
00.0
9.99 sec.
0.10 sec.
10
[N]
[N]
14.5