2180 Air Relief Valve Repair Kits
In practice the valve should be matched to the system to be protected
such that the maximum airflow rate of the valve is never utilized, i.e.
the valve should be capable of relieving a sufficient volume flow rate
of air at the opening pressure to ensure that the system pressure
drops significantly. If the valve is open and the system pressure
continues to rise above the opening pressure then the valve is
relieving less air than is being put into the system. This is a potentially
dangerous situation that may lead to over pressurization. Air relief
valves should always be matched to the system to be protected such
that the relieving airflow rate of the valve at the maximum allowable
system pressure, and ideally at the opening pressure, is well in
excess of the system input flow rate at that same pressure.
Pressure and Vacuum Relief Valve Terminology
2180 AIR RELIEF VALVE RK