Altrad Lescha BX 135 Original Instructions Manual - Page 11
Browse online or download pdf Original Instructions Manual for Mixer Altrad Lescha BX 135. Altrad Lescha BX 135 20 pages.

Repair
Pull plug each time before doing repair
work.
• Switch off machine and pull plug if repair work should be necessary. Do not start machine during repair work.
• Protective devices removed for repairs must be properly remounted before starting the machine.
• Only the manufacturer or companies authorised by the manufacturer may perform repair work on electrical parts or on parts which
affect the space needed to mount electrical equipment.
• Use only unaltered original spare parts. Otherwise, the manufacturer will assume no liability.
• Adjust tooth play (if possible) see P. 15.
Equipment failures
Malfunction
Motor does not start up
Motor hums but does not start
up
Machine
starts
up,
but
becomes blocked at low load
and may switch off auto-
matically
Guarantee
The manufacturer will supply a 2 year warranty for faults in material and/or workmanship. Damage due to improper handling and/or non-
observance of operating will be excluded from the warranty. The warranty will only apply if original spare parts are used. Further liability and
costs are not assumed.
The invoice with the invoice date is proof of warranty claims. The serial number of the device stamped on the rating plate must also be
specified.
Possible cause
⇒ no mains voltage
⇒ defective cable
⇒ thermostat is triggered reason:
− motor overload
− motor not getting enough air owing to
clogged ventilation apertures
⇒ blocked crown gear
⇒ defective condenser
⇒ extension cord is too long or its cross-section
is too small
⇒ socket is too far from mains connection and
the connecting wire's cross section is too small
Remedy
⇒ check fuse protection
⇒ have checked or replaced (electrician)
⇒ allow motor to cool and then find and eliminate
whatever caused the thermostat to respond
⇒ switch off machine, pull plug and clean or
replace the crown gear segments
⇒ send machine to manufacturer or a company
designated by the manufacturer for repairs
⇒ extension cord must be at least 1.5 mm² for a
maximum length of 25 m; the cross-section of
longer cables must be at least 2.5 mm²
10