AUTO FILL AND AUTO DUMP:
The 9000I-HSH ENDEAVOR is equipped with Auto-fill/Auto-Dump capabilities. To use this feature, locate the two hose
ports that are located on the bottom left rear of the machine. The female fitting is the "in" and the male fitting is the "out".
AUTO FILL:
-
Securely connect a garden hose to a faucet or water source.
Securely connect a 3/4" garden hose to the female "IN" port of the ENDEAVOR and turn on the water source to
-
fill your machine. Simply turn the water on, it is not necessary to turn the water on at high pressure.
-
The ENDEAVOR has been outfitted with an automated fill valve that will maintain the appropriate water level.
Make sure the float on the fill valve is free and unobstructed.
-
It is advisable to monitor the machine periodically to prevent flooding or running dry. Inspect garden hoses for
kinks, leaking and damage to the threads.
AUTO DUMP:
Securely connect a 3/4" garden hose to the "out" port of the ENDEAVOR.
-
-
Secure the open end of the garden hose to a drain.
Locate the switch marked "pump out" on the front panel and place it into the on position. This will turn the dump
-
pump on. The dump pump can be run continuously and experience periods of running dry without any negative
effects.
-
Daily cleaning of the intake filter bag and the pump intake filter located in the recovery tank are essential to
preserving the proper function of the pump out feature. It is up to the operator to determine a proper cleaning
schedule as workloads differ from job to job. It is advisable to inspect the filters periodically to gauge what an
appropriate cleaning schedule would be.