OSD MENU
Setup
Language: OSD language selection
Restore Factory Default: Adjusts the parameters to the initial factory
parameters
Blending: OSD window transparency
∙ Low
∙ Medium
∙ High
∙ Off
OSD Duration: Adjusts the time that the OSD menu window remains on
screen
Software Update (USB): Used for firmware upgrade
Mirror:
0. Image with no flip
1. Vertical flip
2. Horizontal flip
3. Rotate
16
AHNET PROTOCOL
Communications protocol
COMMUNICATION
RS422
CONNECTION
RJ45
WIRING
CAT-5
Speed and configuration
BAUD RATE
38400
DATA BITS
8
PARITY
NONE
STOP BITS
1
Wiring Diagram
1. Data TX +
2. Data TX –
3. Data RX +
4. NC
5. NC
6 .Data RX –
7. NC
8. NC
Connection
PINS 1 & 2
The units respond
PINS 3 & 6
The units receive instructions
Protocol to control the monitor by addressable RS422 bus.
You can connect up to 30 monitors on the same RS422 bus.
You can use a AH Interface Ethernet, to control the RS422 bus.
The units should have a set address and the address must start by 1.
Maximum cable length between ends, 500 m/1640 ft.