The Charging
The charging outside the pedelec is started by unlocking the lock, that way you can remove the battery as usual and
charge it in your appartement or garage in your presence.
Turn off the drive system and wait until the LEDs of the battery expire. Only now, you unlock the lock with the key.
Please pay attention that the battery has tob e activated by pushing the capacity indicator button. It is playced on
the left side of the battery.
Start of charging process with the original power supply
First connect the power suply with the battery, then the power supply mains plug!
1. Connect the 3pole charge connector of the original charge plug into the battery. The connector is settled
on the battery's right side.
2. Now connect the power supply with the mains.
3. The charging process starts. The battery's LED which fits to its actual capacity status starts flashing.
Start of charging process with E-Bike Vision charger
Connect the charger to the mains.
•
Turn on the charger and wait until the green LED flashes slowly.
•
Now plug in the charging connector of the charger to the battery.
•
In the charging socket of the battery and in the charging plug of the charger, there are guide slots to prevent
•
the charging plug to be inserted incorrectly. Please turn the charging plug slightly, when you plug it in the
socket of the battery, until it is in its right position. This manifests itself by a slight snap. Now, the charging
plug can be inserted with light pressure. Please do not try to push the charging plug into the charging socket
with too much force, otherwise you could damage the battery or the charger.
Charging process starts and the fan turns on. The LEDs of the battery corresponding to its current state of
•
charge begins to flash.
If charging process does not start immediately, so push the capacity indicator button and wait until the
•
LEDs turn on.
If the battery is almost fully charged (4 LEDs are lighting and the 5th is flashing), the fan will not start
•
turning under certain circumstances, because the charger switches immediately into the so-called
constant voltage mode. Within this mode, the power consumption of the charger is that low that the
running of the fan is not necessary.
Furthermore, the fan will also turn off towards the end of charging process, as it is no longer needed in
constant voltage mode.
During charging, the capacity is indicated by lighting and flashing of the battery's LEDs as follows:
LED 1 flashing:
LED 1 lighting and LED 2 flashing:
LED 1,2 lighting and LED 3 flashing:
LED 1,2,3 lighting and LED 4 flashing:
LED 1,2,3,4 lighting and LED 5 flashing:
LED 1,2,3,4 and 5 lighting:
Date March 2019
Version 06
0 – 19 % charged capacity
20 – 39 % charged capacity
40 – 59 % charged capacity
60 – 79 % charged capacity
80 – 96 % charged capacity
>= 97 % charged capacity