Artidor AR-077 Series User Manual - Page 7

Browse online or download pdf User Manual for Lighting Equipment Artidor AR-077 Series. Artidor AR-077 Series 16 pages. Explosion-safe signal lights

6.
Technical Data
Explosion safety category:
Protection against ignition:
Conformity:
Standards applied:
EC Type Examination Certificate:
Ambient temperature:
Ingress Protection level:
Material housing:
Material transparent dome:
Material mounting bracket:
Light source (Xenon)
Light source (LED):
Lens colors:
Mounting position:
Activation time:
Circumstances of use:
Entries AR-077/011:
Entries AR-077/211:
Connection terminals:
Earth connection:
Weight:
User manual explosion-safe AR-077 signal light
Issue April 2020
ATEX II 2GD
Ex d IIC T6, Ex tD A21 IP65 T80˚C (cable version)
Ex de IIC T6, Ex tD A21 IP65 T80˚C (cable gland version)
2014/34/EU (ATEX 114) and 2014/30/EU (EMC)
EN 60079-0:2006, EN 60079-1:2004, EN 60079-7:2003,
EN 61241-0:2006, EN 61241-1:2004 EN 50081-1 and EN-50082-1
KEMA 07ATEX0046
-20 ˚C to +40 ˚C
IP65 according to EN 60529
Anodized aluminum, colors grey and red
Polycarbonate, impact-resistance > 7 Nm
Stainless steel, uncoated
Xenon bulb, 5 Joule, 1 flash / sec, (8
Multi-LED reflex lamp
Red, orange, yellow, green, blue and clear
As desired (360º)
100%
Exterior and interior use
Factory sealed cable, color coded, 3 x 1 mm², length 3 meters
M20 x 1.5 (2x), cable gland Ø 6-12 mm (1x) and blind plug (1x)
3 x 2.5 mm²
External, stainless steel, 4 mm²
1,170 gram (AR-077/011/...)
1,610 gram (AR-077/211/...)
10
flashes lifetime)
·
6
7 / 16