Custom Crimp D101S Operator's Manual - Page 5

Browse online or download pdf Operator's Manual for Crimp tool Custom Crimp D101S. Custom Crimp D101S 12 pages. Hydraulic hose crimper
Also for Custom Crimp D101S: Operator's Manual (13 pages)

Custom Crimp D101S Operator's Manual

CALIBRATION INSTRUCTIONS

• Place the Pressure Plate, any D100 Series Standard Die Set and the Compression
Ring in the crimper in the order shown.
• Set the Micro-Crimp Adjuster as follows:
Standard Micrometer: "100"
"DC" Micrometer:
Metric Micrometer:
• Bring the ram and pusher down on top of
the compression cone and increase the
pump pressure until the die set is completely
closed and the pump starts to build
pressure.
All D100 Series Crimpers
• Continue increasing the pressure on the compression Cone
until the circumferential white line on the Micro-Crimp Sight
Button just becomes visible above the Micro-Crimp Adjuster
as shown in the illustration.
D101S Series Crimpers (with electric pump)
• The Electric pump should completely close the die set
before the pump shuts off.
• If the white line is not visible or the electric pump does not
shut off when the dies are completely closed, adjust the
calibration adjustment screw under the Micro-Crimp Adjuster
contact button as illustrated. Repeat the calibration
procedure until the above conditions are satisfied.
• When the above conditions are met, the crimper is
calibrated and ready for use.
Do Not use Double Angle Components
"95"
"0"
Page
5