3KO Apollo Micro-2 Manual - Page 2
Browse online or download pdf Manual for Pager 3KO Apollo Micro-2. 3KO Apollo Micro-2 4 pages. Gsm pager/remote control
www.3ko.hu
Functions of LED indications:
When powering-on the green LED must light for a while, otherwise the pager is out of order. Then pager starts the self-examination
taking up some minutes. After this procedure flash by seconds of green LED will indicate the ready-to-operating status.
The summary of possible LED indications :
Green LED:
Flashing by seconds – normal operation
Continuous light – incoming or outgoing call or SMS
Quick flashing - PC connected , ready to download
Yellow LED:
Indicator of active relay
Red LED:
Separated short flashes in case of Errors, as follows:
•
•
•
•
•
Recording SMS messages to SIM-card, using mobile phones
There are three kind of predefinable SMS text messages, which will be ready to send in case of different events.
Delete all incoming, outgoing and predefined SMS messages from SIM, before recording the new messages.
•
Record the SMS #1 message, it will be sent in case of triggering the positive input
•
Record the SMS #2 message, it will be sent in case of triggering the negative input
•
Record the SMS #3 message, it will be sent in case of restoring the positive input
The neccessary condition to send any SMS is to register the appropriate keywords (Possms, Smstel...).
Recording of predefined SMS messages could be done by inserting the SIM into a mobile phone, writing-in the messages using the
keypad, then puting back the SIM into pager. Other method is to write-in the messages into a mobile, then sending the three SMS in
proper order to the pager. Prior to this operation the pager's SMS memory must be empty - for this reason use a remote control SMS
to delete SMS fields in the pager (see keyword Psw)
Programming keywords and parameters
Altel1, Altel2,Altel3, Altel4
The data related to these keywords are the phone numbers which will be dialed by pager when negative input was triggered.
It is not obligatory to insert these keywords, their number is optional. If only SMS message is required, do not insert any of them. The
module will interpret a dialing as a successful call, if the target number will pick up the line. If the call is unsuccessfull, the module
later will repeat the paging to the same number (see Recall keyword).
Bitset
(6 binary digits, if the record is missing then default value is : 100000)
The data related to this keyword is a numeric string of 6 digits, interpreted as follows:
1. digit:
2. digit:
3. digit
4. digit
Apollo micro-2 V6.04
1 flash
phone call was unsuccessful (e.g. the number is busy or out of order)
2 flashes
SMS messaging was unsuccessful
3 flashes
signal strength problem
4 flashes
internal GSM communication errors, automatic restart will follow
5 flashes
SIM-card phone-book records are unreadable or faulty
0 – positive input will trigger when released from supply
1 – positive input will trigger when switched to supply
0 – negative input will trigger when switched to GND
1 – negative input will trigger when released from GND
0 – relay operation is bistable, for each call its status will be changed to opposite
1 – relay operation is monostable, for each call the relay will active for defined seconds
0 – in case of SMS command to relay control, the module will pick up the line, and will answer
with an audio signal (three beeps = Switch-ON / one beep = Switch-OFF)