12 APPENDIX
Terminology, all events and operations details including action key event, LED and Buzzer status.
12.1 System Event Status
Event
System Ready
Standalone mode heartbeat
Event Success
Event Error
Event Timeout
12.2 Touch Sense Button Keylock
Event
Action / Status
Keylock
Enable Lock Key Function
Enable
Success – "In Network mode"
Success – "In Standalone Mode"
Keylock
Disable Lock Key Function
Disable
Success – "In Network mode"
Success – "In Standalone Mode"
Ubitech Ltd.
BVSLWx User Manual
Detail
BVS is Ready to operate after power on or reset.
Standalone Heartbeat without network connection
Finished operation and success
Operation fail or not available
Operation timeout
Key Action
Hold 3 seconds & click 3 times
---
---
Hold 3 seconds & click 3 times
---
---
LED
Green LED ON 2 seconds
Yellow LED blinking
Green LED ON 2 seconds
RED LED blinking 3 times
RED LED ON
LED Status
Yellow LED ON 1 second Red
LED ON 1 second
Yellow LED slow blinking
Yellow LED blinking
Yellow LED blinking
Green LED slow blinking
Yellow LED blinking
13
Date: 9-Jun-2021
Buzzer
2 beep sounds
---
Short beep x 2
Long beep x 3
1" Pulse sound
Buzzer Status
Long beep×1
---
---
Long beep×3
---
---
Version: 0.4.1