Alula RE111P Quick Start Manual

Browse online or download pdf Quick Start Manual for Accessories Alula RE111P. Alula RE111P 2 pages. Indoor motion sensor, pet immune, interlogix / ge compatible

Alula RE111P Quick Start Manual
RE111P
Indoor Motion Sensor, Pet Immune, Interlogix / GE Compatible
1. Specifications
Frequency:
319.5 MHz
Operating Temperature:
32°-120°F (0°-49°C)
Operating Humidity:
5-95% RH non-condensing
Battery:
1x CR123A Panasonic Lithium 3V DC
Battery Life:
5 Years
Compatibility:
Interlogix / GE receivers
Pet Immunity:
Up to a maximum of 85 lbs
Supervisory Interval:
Approximately 60 minutes
Coverage Area:
40 feet by 40 feet, 90° angle
Light Immunity:
2000 Lux
Coverage Pattern:
Side View:
7.5 ft
0
3
6
10 13
16 19
23
26
(feet)
Top View:
0
3
6
10
13
16
19
23
26
29
33
36
40
29 26 23 19 16 13 9 6 3 0 3 6 9 13 16 19 23 26 29
(feet)
2. Package Contents
1x Sensor
4x Screws & Wall Anchors 1x CR123A battery (installed)
2x Sensor Case Screws
1x Manual
3. Component Identification
Case Release Button
29
33 36 40
4. Enrollment
0
To enroll the sensor, set your panel into program mode. Then go to the Learn
3
Sensors menu. Refer to your specific alarm panel instruction manual for details on
6
these menus. To trip the sensor:
10
13
1. Remove the PIR from its back cover mounting plate.
16
2. Pull the Battery Tab -or- Remove and reinstall the CR123A battery to place
19
the sensor in Walk Test Mode. The red LED will begin to flash for 45
23
seconds.
26
a. When the LED stops flashing, the sensor can be triggered by
29
33
b. The sensor will transmit every time motion is detected. Trigger the
36
40
3. Select the appropriate sensor group and number in your panel.
1x Sensitivity Jumper
1x Back Mounting 2-Sided Adhesive Tape
2x Side Mounting 2-Sided Adhesive Tape
Tamper Switch
Sensitivity Jumper
CR123A Battery
Sensor Case Screws
waving your hand in front of the motion sensor.
motion sensor as many times as necessary until the panel
recognizes the sensor's serial number.
4. Exit the panel's programming mode.
Return the PIR to its mounting plate.
5. Mounting
Mount the motion sensor at 7.5 feet (2.3 meters)
above the floor. Press the case release button to
separate the front and back sensor case. The back
case gives access to both the flush mount and
corner mount screw knock outs. Remove the
appropriate knockouts and use the included
screws to mount in the desired mounting
location. It is recommended to ensure there is a
tight seal around the knockouts to prevent bugs
from entering the sensor and causing false
alarms. Replace the front sensor cover to snap
shut and screw in the sensor case screws on the
top and bottom of the back sensor case. The RE111P is intended to be
installed in accordance with the Standard for Installation and
Classification of Residential Burglar Alarm Systems, UL1641 & UL 691 -
Classification of Burglar and Holdup Alarm Systems, UL 681, and is
intended for Residential use only. The RE111P intrusion detection unit
shall be installed in accordance with the Standard for Installation and
Classification of Residential Burglar Alarm Systems, CAN/ULC-S310 and
CSA C22.1, Canadian Electrical Code, Part I, Safety Standard for Electrical
Installations.
6. Sensitivity Jumper Settings
For standard sensitivity motion detection with pet immunity leave the jumper
in the default setting (on). Remove the jumper if increased sensitivity to
movement is desired.
7. Walk Test Mode
Walk test mode can be used to test the motion sensor detection coverage
area. To enter walk-test mode remove the battery for 10 seconds and
re-insert the battery. The red LED will begin to flash indicating that the motion
sensor is warming up. After 45 seconds, the LED will stop flashing which
indicates the motion sensor is ready to detect motion. The LED will illuminate
each time motion is detected. Once the LED goes out, the sensor is ready to
detect motion again. Walk test mode ends after 15 minutes. It is
recommended that the RE111P PIR is tested monthly to ensure proper
function.