Pro Tips
The cover can be removed without removing the wall clip.
Both titanium probes must be in the same puddle for the sensor to detect water.
Tamper detection depends on how the sensor is installed.
• Sensor secured to wall: Tamper is indicated when lifted off the clip.
• Sensor NOT secured to wall: Tamper is indicated when the cover is removed.
When changing the batteries replace both with new batteries.
Specifications
Physical
Housing Dimensions
Weight with Batteries
Mounting Fastener
Environmental
Operating Temperature
Maximum Humidity
Water Resistance
Sensor Specifications
Frequency
Replacement Batteries
Nominal Battery Life
Battery Voltage
Current Draw
Transmitted Indications
Temperature Accuracy
Certification
RE118
WARRANTY
Alula will replace non-products that are defective in their first five
(5) years, and portable products that are defective in their first two
(2) years.
IC NOTICE
This device complies with Industry Canada license-exempt RSS
standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) This device must accept any interference, including interference
that may cause undesired operation of the device.
Le présent appareil est conforme aux cnr d'Industrie Canada
applicables aux appareils radio exempts de licence. L'exploitation
est autorisée aux deux conditions suivantes:
(1) L'appareil ne doit pas produire de brouillage, et
(2) L'utilisateur de l'appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d'en
compromettre le fonctionnement.
IC: 8310A-RE118
2.43 x 2.48 x 1.17 inches (6.2 x 6.3 x 3.0 cm)
1.34 ounces (38 grams)
#6 screw (not provided)
32°F to 120°F (0°C to 49°C)
85% non-condensing relative humidity
IP67 rated (Waterproof for over 30 minutes at 1 meter depth)
319.5 MHz
Two Panasonic CR2032
10 years
3.0 VDC (Nominal) 2.3 VDC (Low)
20 mA (Maximum) 0.5 uA (Quiescent)
Cover Tamper, Wall Tamper, Low Battery, Supervision
+/- 2°C
FCC, IC
Specifications subject to change without notice.
47-0028-01 • RevB • 2018-03-28
Tech Support Line • (888) 88-ALULA (888) 882-5852
FCC NOTICE
This device complies with Part 15 of the FCC rules. Operation is
subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference that may be received,
including interference that may cause undesired operation.
Changes or modifications not expressly approved by Alula could void
the user's authority to operate this equipment.
FCC ID: U5X-RE118
TRADEMARKS
Alula is a trademark owned by Alula Holdings, LLC.
"Interlogix" is a trademark owned by United Technologies Electronic
Controls Inc.
Alula products will function with Interlogix systems. However, no
Alula product is produced by, endorsed by, or is officially associated
with Interlogix.
Alula recommends verifying proper enrollment and operation, per
control panel installation instructions, at installation.
alula.net