QUICKSTART "BASIC" GUIDELINES FOR MODEL 9000 - DIP-SWITCH AND WIRING REFERENCE
Model 9000 is intended for installation only on slide gates used for vehicles.
Pedestrians must be supplied with a separate access opening.
For safety and installation instructions, please refer to the Installation/Owner's manual.
SW 1 DIP-Switches
Switch
Function
Setting
Primary
Opening direction
1
Operator
using ON setting.
Opening
Direction
Secondary
Opening direction
Operator
using ON setting.
2
Opening
Direction
OFF
The output wired to terminal #4 becomes the output from the exit loop detector
Exit Loop Port
Output
3
plugged into the EXIT Loop port.
Full Open Input
Normal Setting. Terminal #4 is a normal full open input.
ON
Auto-close timer is OFF. Manual input required to close gate.
OFF
Auto-Close
4
SW 1
Timer
ON
Normal Setting. Auto-close timer is ON. Adjustable from 1-23 seconds.
Normal Setting. Input to terminal #6 and reverse loop will reverse gate during
OFF
Reverses Gate
close cycle.
5
Input to terminal #6 and/or reverse loop will stop gate during close cycle – gate will
ON
Stops Gate
continue to close after input to terminal #6 and/or reverse loop are cleared (Helps
prevent tailgating).
Single Operator
OFF
Normal Setting. Switch must be OFF for single operator.
6
Dual Operators
ON
Switch must be ON when primary/secondary (dual) gates are used.
Normal Setting. Relay activates when gate is at open limit.
7-OFF
8-OFF
Relay activates when gate is not closed.
7-OFF
8-ON
7 and 8
Relay
Relay activates when gate is opening and open.
7-ON
8-OFF
Relay activates during opening and closing cycle.
7-ON
8-ON
SW 2 DIP-Switches
Switch
Function
Setting
Normal Setting. Timer will function normally.
OFF
1
Quick-Close
ON
Opening gate will stop and begin to close as soon as all reversing inputs (Reverse
Timer Override
loops, photo sensors) are cleared regardless of the distance the gate has opened.
Normal Setting. Magnetic lock is not used.
OFF
2
Magnetic lock
Magnetic lock is used and connected to terminals 9 and 12.
ON
SW 2
3
Normal Setting. Switch 3 MUST be turned ON for Model 9000 operator.
ON
4
Normal Setting. Switch 4 MUST be turned OFF for Model 9000 operator.
OFF
Description
Opening direction
using OFF setting.
Changes direction operator will cycle open
upon initial AC power up and open command.
Opening direction
Changes direction operator will cycle open
using OFF setting.
upon initial AC power up and open command.
Note: After a DIP-switch setting is changed, power must be turned
OFF and then turned back on for the new setting to take affect.
Description
Important:
Controls intended for user activation must be located at least six (6) feet away from any moving part
of the gate and where the user is prevented from reaching over, under, around or through the gate to operate the
controls. Emergency access controls only accessible by authorized personnel (e.g., fire, police, EMS) may be
placed at any location in the line-of-sight of the gate.
4-Pin Non-Removable Terminal
3-Button Control Station
Use a standard 4-wire 3-button
Note: When
control station. DoorKing's
using 3-button
3-wire 3-button control station
control station
3-Pin With
cannot be used.
AND interlock
Jumper
switch together,
#1 Open N.O.
#3 terminal
E N
O P
(N.C.) must be
#2 Close N.O.
wired in series.
S E
C L O
Place jumper
#3 Stop N.C.
O P
on bottom
S T
2 pins when
#4 Com
using 4-pin
terminal.
To #4 Com
Entrapment Protection must be provided for the gate system where the risk of
entrapment or obstruction exists. The operator will NOT run without one or
more monitored type B1 or B2 external entrapment protection devices in
EACH direction of gate travel (minimum of 2 external devices required).
1
Com
1
2
Full
Open
#5 Terminal Note: Any opening device connected to terminal #5 will open the gate to
2
3
the partial open setting. Secondary entrapment protection devices will also open the
1
gate to the partial open setting. If the inherent reverse sensor gets activated during the
3
2
Full
4
close cycle, it will always fully open the gate.
Open
3
4
4
5
Partial
Open
IMPORTANT:
1477-010
5
SW1
ON
6
to each input. An OPTIONAL Expansion Kit (sold
separately) will allow connection for additional devices.
1
2 3 4
6
UL 325
7
DIP switches
7
1
OB
8
2
CB
Open Beam necessary when area between
8
UL 325
3
gate and wall is between 2 1/4" and 16".
OE
9
Terminal
4
CE
9
UL 325 DIP-Switches
5
G
10
ON
6
10
G
1
2 3 4
11
NC
NO
11
12
CLOSE Beam REVERSE
12
OPEN Edge/Beam REVERSE
13
Com
13
CLOSE Edge/Beam REVERSE
14
14
(Common) Ground
15
(Common) Ground
15
16
16
#9 Normally
Close
17
24 Volt 1 amp max.
17
18
18
19
19
20
20
UL 325 August
2018 Standard
Normally Closed
Interlock Switch
Operator Cycling
N.C.
Com
N.O.
Lock Engaged
1
2
3
Operator Stopped
N.C.
3-Pin
Com
Remote
N.O.
Terminal
Lock Disengaged
Power is limited
To #3 Stop N.C.
to 250 mamps.
#2 Normally Open
#4 Normally Open
External Entrapment
Only 1 monitored Device can be connected
Protection Devices
Close Beam
Wall
Filler Post If necessary
Open Beam
Open Edge
Closed Gate
DIP-switches MUST be turned ON
for each device wired to terminal.
UL 325 Terminal
1
OPEN Beam STOP
N.C.
UL 325 switch 1
2
N.C.
UL 325 switch 2
3
N.C.
N.C.
UL 325 switch 3
4
N.C.
UL 325 switch 4
5
Connect ONLY MONITORED
Devices
6
IMPORTANT:
Photo sensors must use
Magnetic Lock
Normally Closed (NC) contacts with the beam
Power (24-Volt DC) and
set for light operate (relay activated when
beam is not obstructed). Some manufacturer's
logic output. Power is shut
photo sensor contacts are labeled as Normally
off .5 sec. prior to gate
Open (NO) but their relay functions the same
starting and remains off
way as described above. See specific
while gate is opening and
manufacturer's wiring manual for more
information about their specific relay function.
in the open position.
120 S. Glasgow Avenue
Inglewood, California 90301
U.S.A.
3-Wire Radio
Receiver
we
r
Po
Safety
Opening
Device
SW 1
Switch 3 Must be ON.
Telephone
Entry
Stand-Alone
Key Switch
Stand-Alone
Keypad
Stand-Alone
Card Reader
Note: All stand-alone
and telephone entry devices must
use a separate power source.