Alula RE934ZT Quick Start Manual - Page 3
Browse online or download pdf Quick Start Manual for Computer Hardware Alula RE934ZT. Alula RE934ZT 4 pages. Translator and zwave expansion card
Also for Alula RE934ZT: Manual (4 pages)
GE, DSC, & Napco Sensor Enrollment
1. Place Panel in RF Enrollment mode.
2. Enroll the following sensor types as instructed,
• Smoke Sensors - Press and hold the test button until the sensor issues 2 complete
alarm cadences, then release and wait 30 seconds. If the sensor does not enroll, try
holding the test button longer before releasing.
Interlogix (formerly GE) SDX-135Z Smoke Sensor: Enroll by pressing and
releasing the test button quickly.
• Panic Buttons (Napco panics not supported) - Press and hold the panic button
until the panel beeps confirming enrollment.
• Key Fobs - Press and hold the LOCK/AWAY button until the panel beeps
confirming enrollment.
• Tilt Sensors - Ensure the garage door is closed. Remove the sensor cover to
tamper the device. With the cover removed, open the garage door, then close the
garage door and re-install the cover.
• Door/Window Sensors - Cycle the contact three times (Open-Closed-Open or
Closed-Open-Closed), allowing several seconds between each change.
• Glass Break/Shock - Tamper the sensor
• Motion Sensors (PIR) - Tamper the sensor
• Environmental Sensors (Flood, Freeze, Heat, etc.) - Cycle the tamper switch three
times allowing 8 seconds between each change.
Note: Input index and alarm type must be verified, and modified if needed,
using the Installer App or dealer portal.
• CO Sensors - Press and hold the test button until the sensor beeps twice, continue
holding for one second, then release and wait 30 seconds. If the sensor does not
enroll, try holding the test button longer before releasing.
DSC CO Sensor Enrollment Note: If a DSC CO sensor does not enroll using
the test button, wait 30 seconds, then try enrolling by tampering the sensor.
Sensor Testing
Check the Replace-By-Date of all Smoke and CO sensors.
STOP
If expired, the sensor must be replaced with a new sensor.
Pro Tip: Sensor batteries should be replaced now to reduce future service calls
1. Verify all settings for each sensor using the Installer App or dealer portal.
• Device Type
• Siren Type
• Alarm Type
• Entry/Exit Delay Type
• Active Arming Levels
• Additional Options (Reporting Delay, Bypass Allowed, Chime, Follower, etc)
2. Test All Smoke and CO sensors by pressing the test button and verifying the panel
goes into the correct alarm type or indicates the correct alarm test type.
3. Test all remaining sensors and peripherals to verify proper operation.