ARTRAY ARTCAM-024TFF Series Instruction Booklet - Page 8
Browse online or download pdf Instruction Booklet for Digital Camera ARTRAY ARTCAM-024TFF Series. ARTRAY ARTCAM-024TFF Series 13 pages. Usb2.0 multi-head synchronous cmos camera
5. Connect the Camera
5-1 How to connect a camera
Camera Cable
Camera Head
5-2 Shutter Speed
Shutter speed can be changed on the standard viewer software ART-Viewer.
The shutter speed is set directly on the sensor register, so please refer to the following formulas for the real exposure
time.
Model
ARTCAM-024TFF-2CAM
ARTCAM-024TFF-3CAM
ARTCAM-024TFF-4CAM
Camera Control Unit
Range : 1~32767(Exposure Time : 1/16042~2 sec)
Exposure Time=(Shutter Value×(640+88))×0.0833 [μsec]
Range : 1~32767(Exposure Time : 1/32086~1 sec)
Exposure Time=(Shutter Value×(640+88))×0.0417 [μsec]
- 8 -
USB2.0 Cable
USB2.0 Port
AC Adapter
*Number of camera head will vary
depending on products.
Method
PC
Power
*640×480 at 12MHz
*640×480 at 24MHz