Alvarion BreezeACCESS VL 3.1 Release Note - Page 8
Browse online or download pdf Release Note for Network Hardware Alvarion BreezeACCESS VL 3.1. Alvarion BreezeACCESS VL 3.1 8 pages. Wireless broadband platform
some cases, setting the "Max Tx Power" in the "Maximum Transmit Power Table" does not
actively set the configured value in the device, and it is recommended to use telnet for that
purpose.
•
The Sub-Band parameter is not available through export unit parameters feature (CFG file).
9. Fixed Issues
•
In previous versions the prioritization mechanism was disabled when the traffic rate reached
the maximum information rate supported by the SU. This problem was solved.
•
In some scenarios, units may stop transmitting after a period of typically over several days (all
incoming packets from the Ethernet port are discarded by the MIR/CIR mechanism). This
problem was solved in version 3.1.25.
•
In some scenarios of heavy traffic and/or interferences an AU may reset upon new
association/re-association of an SU. Some of these scenarios include Best AU feature on.
Typical error messages were produced: "MIR/CIR Priority Queue problem (3): PQ is empty:" or
"FTL - Fragments in TX AU". This problem was solved with 3.1.25.
HTTP://WWW.ALVARION.COM
page 8 of 8
ALVARION LTD.
21A HABARZEL STREET,
TEL AVIV, 69710,
ISRAEL
TEL: 972-3-6456262
FAX: 972-3-6456222