Aiolos PuriClean PuCl-1000-U User Manual - Page 14
Browse online or download pdf User Manual for Air Cleaner Aiolos PuriClean PuCl-1000-U. Aiolos PuriClean PuCl-1000-U 17 pages.
Operation
14
Possible errors / Problem solving
UNIT FUNCTIONS
3. Alarms
3 different alarms can be displayed.
1. "PRE FILTER" Alarm
This alarm is timed and is displayed after 1,000 operating
hours. This corresponds to a minimum filter maintenance at
average pollution conditions.
The filter alarm is reset after cleaning by pressing "FAN
SPEED". Press and hold the key for about 5 seconds. Then the
warning light goes out.
2. "HEPA"
-Alarm; The Hepa filter lights up when it reaches
the full level that affects the performance of the device. If you
replace the HEPA filter, the filter differential pressure sensor
will detect it and the warning light will go out.
3. "UVC" Alarm
. This alarm is timed and is displayed after
9,000 operating hours or if the lamp is defective. After
replacing the UV-C lamp
The "UVC" alarm is reset after the UV-C lamp has been
replaced by pressing "FAN SPEED". Press and hold the key for
about 5 seconds. The warning lamp then goes out.
The UV-C lamp must be disposed of in accordance with the
applicable waste disposal laws!
Error
Possible causes
Checking the electrical
Connections
Unit does not work
Is voltage available at the socket?
Check whether suction and
discharge openings are blocked
The device does
not blow out air
Fan does not run?
Are the air inlets and outlets free
accessible?
Das Gerät filtert nicht
ausreichend
Filters have not been used for a long time
cleaned.
Strong cigarettes or similar
in the room air.
Luft aus dem Gerät riecht
nicht frisch
Filter service life and contamination
monitor.
UV-C Lamp activated?
UV-C Lamp does not work.
UV-C Checking the lamp contact
in the bracket.
1
2
3
Solution
Visual inspection and checking whether
plug connections are correctly positioned.
Check fuse, otherwise consult
a qualified technician.
Foreign body covers from the device
remove. Keep distance from the wall.
Ensure that the ON switch is activated
Eliminate possible blockages and
pay attention to the necessary distance
Filter cleaning / change.
Odour fades after some time,
because the effect of the activated
carbon filter takes effect.
Filter replace and clean the device
UV-C Lamp switch on at the
control panel
UV-C making contact
EN