Et ET1000 Installer's Instructions - Page 5

Browse online or download pdf Installer's Instructions for Gate Opener Et ET1000. Et ET1000 13 pages. Sliding gate operator commercial/industrial 1000kg mass

2. Installation

2.1 Cable requirements.
E
F
H
A
B
C
D
E
G
H
D
C
G
Intercom cable. As per manufacturer's spec.
Safety infra red beams transmitter cable (0,5mm x 2)
Safety infra red beams receiver cable (0,5mm x 4)
Coutesy light cables 220Vac (1,5mm x 3)
Earth spike cable (2,5mm x 1)
F
Electrical supply 220Vac (2,5mm x 3)
Loop detector feeder (1,5mm x 1 looped)
Intercom cable. (As per manufacturer's spec.
plus 0,5mm x 2 for push button trigger)
A
B
5
D