Fleck 3200ET Service Manual - Page 6

Browse online or download pdf Service Manual for Control Unit Fleck 3200ET. Fleck 3200ET 12 pages. Remote meter

3200ET Remote Meter
Control Operation (Cont'd.)
Timeclock Regeneration Systems -
In Normal Operation the Time Of Day Display will be viewed at all times. The control will operate normally until the days
since the last regeneration reaches the preset number of days. Once this occurs, a regeneration cycle will then be
initiated immediately at the preset Regeneration Time.
Remote Meter Immediate Regeneration Systems -
In Normal Operation the Time Of Day Display will alternate being viewed with the Volume Remaining Display. Water
flow through the unit is indicated by the Meter Arrow that will flash in a direct relationship to flow rate. As treated water
is used, the Volume Remaining Display will count down from a maximum value to zero. Once this occurs a regeneration
cycle will then be initiated immediately.
For Example:
525 Gallons of Water Remaining
(Timer in Service)
(Water Flowing, Meter Arrow Flashing)
Sensor Immediate Regeneration Systems -
In Normal Operation the Time Of Day Display will be viewed at all times. The control will operate normally until a valid
sensor input signal is received. Once this occurs, a regeneration cycle will then be initiated immediately. The Sensor
Input Arrow will flash until the signal is determined to be valid.
Sensor Delayed Regeneration Systems -
In Normal Operation the Time Of Day Display will be viewed at all times. The control will operate normally until a valid
sensor input signal is received. Once this occurs, a regeneration cycle will then be initiated immediately at the preset
Regeneration Time. The Sensor Input Arrow will flash until the signal is determined to be valid. Then the Reserve
Arrow will begin to flash as an indication that reserve capacity is being used.
For Example:
12:58 P.M. With Invalid Sensor Signal
(Timer in Service)
(Sensor Arrow Flashing)
For Example:
12:59 P.M. With Valid Sensor Signal
(Timer in Service)
(Sensor Arrow On)
(Reserve Arrow Flashing) (Delayed Regen)
Immediate Regeneration Systems With Days Between Regeneration Override Set -
When the control reaches its set Days Since Regeneration Override value a regeneration cycle will be initiated
immediately. This event occurs regardless of the Volume Remaining display having reached zero.
Delayed Regeneration Systems With Days Between Regeneration Override Set -
When the control reaches its set Days Since Regeneration Override value a regeneration cycle will be initiated at the
preset Regeneration Time. This event occurs regardless of the Volume Remaining display having reached the
calculated reserve capacity.
Page 6
Printed in U.S.A.